Measurement of Hemoglobin A1c from Filter Papers for Population-Based Studies

Author:

Egier David A1,Keys Judy L1,Hall S Kim1,McQueen Matthew J123

Affiliation:

1. Clinical Research and Clinical Trials Laboratory (CRCTL), Hamilton General Hospital, Hamilton, Ontario, Canada

2. Population Health Research Institute, Hamilton Health Sciences, Hamilton, Ontario, Canada

3. Department of Pathology and Molecular Medicine, McMaster University, Hamilton, Ontario, Canada

Abstract

BACKGROUNDStability and transport challenges make hemoglobin (Hb) A1c measurement from EDTA whole blood (WB) inconvenient and costly for large-scale population studies. This study investigated Hb A1c measurement from WB blotted on filter paper (FP) in a Level I National Glycohemoglobin Standardization Program (NGSP)-accredited laboratory.METHODSThree Bio-Rad Variant™ II HPLC instruments and WB and FP specimens were used. Precision, accuracy, linearity, and readable total area of the 6.5-min (β-thalassemia method) Variant II HbA2/HbA1c Dual Program were assessed. Hb A1c stability was measured using in-house FP QC samples. The INTERHEART (a study of the effect of potentially modifiable risk factors associated with myocardial infarction in 52 countries) and CURE (Clopidogrel in Unstable Angina to Prevent Recurrent Events) studies provided chromatographs for morphometric analyses and interoperator variability experiments. Statistical analyses were performed to assess long-term sample stability, WB vs FP agreement, and significance of Hb A1c peak integration.RESULTSIntra- and interassay CVs were ≤2.00%. Total area counts between 0.8 and 5.5 × 106 μV/s produced accurate Hb A1c results. The regression equation for agreement between WB(x) and FP(y) was as follows: y = 0.933x + 0.4 (n = 85). FP QC samples stored at −70 °C and tested over approximately 3 years yielded CVs of 1.72%–2.73% and regression equations with slopes of −1.08 × 10−4 to 7.81 × 10−4. The CURE study, with better preanalytical preparation, achieved a 97% reportable rate, and the reportable rate of the INTERHEART study was 85%.CONCLUSIONSThe FP collection method described provided accurate, robust, and reproducible measurement of Hb A1c using the Bio-Rad Variant II HPLC autoanalyzer when FP specimens were prepared according to standardized protocols, and analyses were performed in an NGSP-certified laboratory, supporting the use of FP collection cards in large multinational studies.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3