Serum Free Light Chains: An Alternative to the Urine Bence Jones Proteins Screening Test for Monoclonal Gammopathies

Author:

Hill Peter G1,Forsyth Julia M1,Rai Baldeep1,Mayne Stewart1

Affiliation:

1. Departments of Chemical Pathology and Clinical Haematology, Derbyshire Royal Infirmary, Derby Hospitals National Health Service Foundation Trust, Derby, United Kingdom

Abstract

Abstract Background: Retrospective analyses have established the role of quantitative serum free light chains (FLCs) in the diagnosis of monoclonal light chain disorders. The aims of this study were to assess (a) whether the addition of serum FLCs to serum protein electrophoresis (SPEP) identified additional patients with monoclonal gammopathies; (b) whether serum FLC measurements could replace urinalysis for Bence Jones protein (BJP); and (c) the cost/quality implications of routinely measuring serum FLCs. Methods: Serum FLCs were added to consecutive requests for SPEP from August to November 2004 and measured by automated immunoassay. Results: Seventy-one of 923 patients had abnormal serum FLC ratios. Seven patients with monoclonal gammopathies and 1 patient with malignant lymphoma (but no monoclonal band) were detected among 43 patients with negative SPEP but positive serum FLC ratios. Thirty-five patients with negative SPEP had false-positive serum FLC ratios. The false-positive rate for a ratio >1.65 was higher than previously described and associated with polyclonal increases in immunoglobulins and renal impairment. Serum FLC ratios were normal in 2 of 13 patients with low-level persistent urine BJP. However, no significant pathology would have been missed by replacing BJP with serum FLCs. Revenue and manpower savings offset 60% of the costs of serum FLCs. Conclusions: Additional diagnostic information is gained by adding serum FLCs to SPEP as first-line tests for investigating possible B-cell disorders. The quality of the diagnostic service is enhanced by more confident exclusion of light chain disorders and improved interpretive assessment of SPEP and immunofixation electrophoresis.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3