Automated Chemiluminescence-Immunoassay for Aldosterone during Dynamic Testing: Comparison to Radioimmunoassays with and without Extraction Steps

Author:

Schirpenbach Caroline1,Seiler Lysann23,Maser-Gluth Christiane4,Beuschlein Felix3,Reincke Martin1,Bidlingmaier Martin1

Affiliation:

1. Ludwig-Maximilians-University, Medizinische Klinik Innenstadt, Munich, Germany

2. Centre Hospitalier Universitaire Vaudois, Département de médecine interne Lausanne, Lausanne, Switzerland

3. Albert-Ludwigs-University, Medical Department 2, Freiburg, Germany

4. Ruprecht-Karls-University, Institute of Pharmacology, Heidelberg, Germany

Abstract

Abstract Background: Measurements of aldosterone have become more common since the recognition that primary aldosteronism is a more frequent cause of hypertension than previously believed. Our aim was to compare concentrations reported by 4 assays for samples obtained after saline infusion during dynamic testing. Methods: We tested 104 participants (27 with primary aldosteronism, 30 with essential hypertension, and 47 healthy controls) with the intravenous saline infusion test (2.0 L isotonic saline over 4 h), with repetitive sampling. In all blood samples, aldosterone concentration was measured by an in-house RIA after extraction and chromatography, by 2 commercially available RIAs without extraction (Aldosterone Maia, Adaltis; Active Aldosterone, Diagnostics Systems Laboratories) and by an automated CLIA (Advantage, Nichols Institute Diagnostics). Results: Correlation coefficients for results of pairs of assays ranged from 0.74 to 0.98. Agreement between commercial assays and in-house RIA was best at the low to intermediate concentrations after saline infusion. Mean (SD) Adaltis and DSL RIA results were 2- to 3-times higher [healthy participants: 78 (25) ng/L and 56 (18) ng/L, respectively] than those obtained by Nichols CLIA [17 (8) ng/L] and in-house RIA [23 (18) ng/L]. Aldosterone concentrations measured by the Nichols CLIA were below the limit of detection (limit of the blank) in 27 of 47 healthy participants. Conclusions: Aldosterone concentrations reported by the Adaltis and DSL nonextraction RIAs were consistently higher than those produced by the Nichols CLIA and the in-house RIA. The convenient Nichols CLIA showed better agreement with the in-house RIA, but the concentrations in healthy participants were frequently undetectable by this method. Uncritical application of cutoff values from the literature must be avoided.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Reference24 articles.

1. McKenna T, Sequeira S, Heffernan A, Chambers J, Cunningham S. Diagnosis under random conditions of all disorders of the renin-angiotensin-aldosterone axis, including primary aldosteronism. J Clin Endocrinol Metab1991;73:952-957.

2. Mantero F, Bedendo O, Opocher G. Does dynamic testing have a place in the modern assessment of endocrine hypertension?. J Endocrinol Invest2003;26:92-98.

3. Cartledge S, Lawson N. Aldosterone and renin measurements. Ann Clin Biochem2000;37:262-278.

4. Bayard F, Beitins I, Kowarski A, Migeaon C. Measurement of plasma aldosterone by radioimmunoassay. J Clin Endocrinol Metab1970;31:1-6.

5. Segre G, Brown E. Measurement of Hormones. Wilson J Foster D Kronenberg H Larsen P eds. Williams Textbook of Endocrinology1998;Vol. 9 ed.:43-54 WB Saunders Philadelphia. .

Cited by 131 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3