AbstractBackground: The BTA TRAK™ and BTA stat™ tests for bladder cancer use monoclonal antibodies (mAbs) X13.2 and X52.1 to detect factor H (FH)-related material in urine. The exact ligands remain unknown.Methods: Western blot analyses of purified FH, recombinant factor H-related protein 1 (FHR-1), and serum and urine samples were used to identify the ligands of X13.2 and X52.1. Recombinant FH constructs were used to identify the target sites of X13.2 and X52.1. To analyze whether natural ligands of FH could compete with its recognition by the capture mAb X52.1, we used surface plasmon resonance analysis. The role of the ligands of X52.1 in the BTA TRAK assay was tested with use of purified proteins and FH-depleted samples.Results: X13.2 bound to domain 3 of FH and FH-like protein 1, whereas X52.1 bound to domain 18 of FH and to FHR-1. Using specific FH depletion from a bladder cancer patient’s urine and purified FH, we demonstrated that FH is the ligand recognized by the BTA TRAK test. By contrast, FHR-1 in urine reduced the FH-dependent test signal.Conclusions: FH is a tumor marker for bladder cancer. To reveal the presence of bladder cancer, the BTA TRAK assay detects FH, whereas FHR-1 is able to partly inhibit this detection. This indicates a special mechanism for a diagnostic immunoassay based on the combined effect of simultaneous positive and negative signals in a single sample.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 58 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3