Metrologic Traceability of Total Thyroxine Measurements in Human Serum: Efforts to Establish a Network of Reference Measurement Laboratories

Author:

Thienpont Linda M1,Van Uytfanghe Katleen1,Marriot John2,Stokes Peter2,Siekmann Lothar3,Kessler Anja3,Bunk David4,Tai Susan4

Affiliation:

1. Laboratory for Analytical Chemistry, Faculty of Pharmaceutical Sciences, Ghent University, Gent, Belgium

2. Laboratory of the Government Chemist, Teddington, United Kingdom

3. Institute for Clinical Biochemistry, University of Bonn, Bonn, Germany

4. National Institute of Standards and Technology, Gaithersburg, MD

Abstract

Abstract Background: Assuring/demonstrating metrologic traceability of in vitro diagnostics necessitates the availability of measurand-specific reference measurement systems (RMSs) and the possibility for industry to work with competent reference measurement laboratories (RMLs). Here we report the results of a European project to investigate the feasibility of developing a RMS for serum total thyroxine. Methods: Four candidate RMLs (cRMLs) developed/implemented variants of a candidate reference measurement procedure (cRMP) based on isotope dilution–liquid chromatography–mass spectrometry. The sole constraint implemented was calibration with a common thyroxine primary calibrator. The RMPs were externally validated and assessed for comparability in round-robin trials using common samples, i.e., 5 lyophilized and 33 frozen native sera. At the same time, the performance of the cRMLs organized in a network was assessed. For uniform external quality assessment, common performance specifications were agreed on. Results: All cRMLs performed the cRMPs with fulfillment of the predefined specifications: total and between-laboratory CVs ≤2.0% and 2.5%, respectively, and a systematic deviation ≤0.9%, estimated with a target assigned from the mean of means obtained by the cRMLs. The mean expanded uncertainty for value assignment to the native sera was 2.1%. Conclusions: A network of cRMLs, with externally conformed competence to properly perform RMPs, has been established. Performance specifications were defined and will form the basis for admittance of new network members. A serum panel, successfully targeted during the validation process, is available for split-sample measurements with commercial routine measurement procedures. The model can now be used for other measurands for which traceability to the Système International d’Unités is needed.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Reference34 articles.

1. Cali JP. An idea whose time has come. Clin Chem1973;19:291-293.

2. Uriano GA, Gravatt CC. The role of reference materials and reference methods in chemical analysis. CRC Crit Rev Anal Chem1977;6:361-411.

3. Tietz NW. A model for a comprehensive measurement system in clinical chemistry. Clin Chem1979;25:833-839.

4. Stamm D. Reference materials and reference methods in clinical chemistry. J Clin Chem Clin Biochem1979;17:283-297.

5. Maas AH, Weisberg HF, Burnett RW, Muller-Plathe O, Wimberley PD, Zijlstra WG, et al. Approved IFCC methods. Reference method (1986) for pH measurement in blood. International Federation of Clinical Chemistry (IFCC), Expert panel on pH, blood gases and electrolytes. J Clin Chem Clin Biochem1987;25:281-289.

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3