Standardized Peptidome Profiling of Human Urine by Magnetic Bead Separation and Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Author:

Fiedler Georg Martin1,Baumann Sven1,Leichtle Alexander1,Oltmann Anke1,Kase Julia1,Thiery Joachim1,Ceglarek Uta1

Affiliation:

1. Institute of Laboratory Medicine, Clinical Chemistry and Molecular Diagnostics, University Hospital, Leipzig, Germany

Abstract

AbstractBackground: Peptidome profiling of human urine is a promising tool to identify novel disease-associated biomarkers; however, a wide range of preanalytical variables influence the results of peptidome analysis. Our aim was to develop a standardized protocol for reproducible urine peptidome profiling by means of magnetic bead (MB) separation followed by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS).Methods: MBs with defined surface functionalities (hydrophobic interaction, cation exchange, and metal ion affinity) were used for peptide fractionation of urine. Mass accuracy and imprecision were calculated for 9 characteristic mass signals (Mr, 1000–10 000). Exogenous variables (instrument performance, urine sampling/storage conditions, freezing conditions, and freeze-thaw cycles) and endogenous variables (pH, urine salt and protein concentrations, and blood and bacteria interferences) were investigated with urine samples from 10 male and 10 female volunteers.Results: We detected 427 different mass signals in the urine of healthy donors. Within- and between-day imprecision in relative signal intensities ranged from 1% to 14% and from 4% to 16%, respectively. Weak cation-exchange and metal ion affinity MB preparations required adjustment of the urinary pH to 7. Storage time, storage temperature, the number of freeze-thaw cycles, and bacterial and blood contamination significantly influenced urine peptide patterns. Individual urine peptide patterns differed significantly within and between days. This imprecision was diminished by normalization to a urinary protein content of 3.5 μg.Conclusion: This reliable pretreatment protocol allows standardization of preanalytical modalities and facilitates reproducible peptidome profiling of human urine by means of MB separation in combination with MALDI-TOF MS.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 151 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3