Molecular Heterogeneity Has a Major Impact on the Measurement of Circulating N-Terminal Fragments of A- and B-Type Natriuretic Peptides

Author:

Ala-Kopsala Minna1,Magga Jarkko2,Peuhkurinen Keijo2,Leipälä Jaana3,Ruskoaho Heikki4,Leppäluoto Juhani1,Vuolteenaho Olli1

Affiliation:

1. Departments of Physiology and

2. Department of Internal Medicine, Kuopio University Hospital, Kuopio, Finland

3. Department of Pediatrics, Helsinki University Hospital, Helsinki, Finland

4. Pharmacology and Toxicology, Biocenter Oulu, University of Oulu, Oulu, Finland

Abstract

AbstractBackground: The N-terminal fragments of A- and B-type natriuretic peptides (NT-proANP and NT-proBNP) are powerful markers of cardiac function. The current assays require refinement with regard to standardization with native calibrators and the ability to detect the actual circulating forms.Methods: The following peptides were prepared with recombinant methods: NT-proANP, NT-proBNP, proBNP1–108, and Tyr0-proBNP77–108. Fifteen peptides of 13–22 amino acids, spanning the sequences of NT-proANP and NT-proBNP, were prepared by solid-phase peptide synthesis. Two immunoassays for NT-proANP and four for NT-proBNP were set up, each with a different epitope specificity. The assays were applied for the measurement of NT-proANP and NT-proBNP in healthy individuals and in patients with acute myocardial infarction. The circulating molecular forms were analyzed by gel-filtration and reversed-phase HPLC.Results: According to the HPLC analyses, circulating NT-proANP consists mainly of the full-length peptide, with some degradation at both ends. In contrast, circulating NT-proBNP is very heterogeneous. Most immunoreactive NT-proBNP is significantly smaller in size than NT-proBNP1–76, with truncation at both termini. The smallest fragments can be detected by assays directed at the central part of NT-proBNP only; assays directed at the ends gave 30–40% lower values. Despite the difference, the various assays correlated reasonably well with each other (r2 = 0.77–0.85). In patients with acute myocardial infarction, NT-proANP and NT-proBNP concentrations were 1.8–2.3 and 4.2–4.5 times higher than in healthy individuals. The development of heart failure further increased the concentrations.Conclusions: Molecular heterogeneity of the circulating forms causes a serious risk of preanalytical errors in assays for NT-proBNP and, to a lesser extent, NT-proANP. The development of a sandwich assay for NT-proBNP would be especially challenging. The most robust and reliable assays use antibodies directed at the central portions of NT-proANP or NT-proBNP.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3