Prognostic Performance of a High-Sensitivity Cardiac Troponin I Assay in Patients with Non–ST-Elevation Acute Coronary Syndrome

Author:

Bohula May Erin A1,Bonaca Marc P1,Jarolim Petr2,Antman Elliott M1,Braunwald Eugene1,Giugliano Robert P1,Newby L Kristin3,Sabatine Marc S1,Morrow David A1

Affiliation:

1. TIMI Study Group, Cardiovascular Division, Department of Medicine and

2. Department of Pathology, Brigham and Women's Hospital, Boston, MA

3. Duke Clinical Research Institute, Duke University, Durham, NC

Abstract

Abstract BACKGROUND High-sensitivity assays for cardiac troponin enable more precise measurement of very low concentrations and improved diagnostic accuracy. However, the prognostic value of these measurements, particularly at low concentrations, is less well defined. METHODS We evaluated the prognostic performance of a new high-sensitivity cardiac troponin I (hs-cTnI) assay (Abbott ARCHITECT) compared with the commercial fourth generation cTnT assay in 4695 patients with non–ST-segment elevation acute coronary syndromes (NSTE-ACS) from the EARLY-ACS (Early Glycoprotein IIb/IIIa Inhibition in NSTE-ACS) and SEPIA-ACS1-TIMI 42 (Otamixaban for the Treatment of Patients with NSTE-ACS) trials. The primary endpoint was cardiovascular death or new myocardial infarction (MI) at 30 days. Baseline cardiac troponin was categorized at the 99th percentile reference limit (26 ng/L for hs-cTnI; 10 ng/L for cTnT) and at sex-specific 99th percentiles for hs-cTnI. RESULTS All patients at baseline had detectable hs-cTnI compared with 94.5% with detectable cTnT. With adjustment for all other elements of the TIMI risk score, patients with hs-cTnI ≥99th percentile had a 3.7-fold higher adjusted risk of cardiovascular death or MI at 30 days relative to patients with hs-cTnI <99th percentile (9.7% vs 3.0%; odds ratio, 3.7; 95% CI, 2.3–5.7; P < 0.001). Similarly, when stratified by categories of hs-cTnI, very low concentrations demonstrated a graded association with cardiovascular death or MI (P-trend < 0.001). Use of sex-specific cutpoints did not improve prognostic performance. Patients with negative fourth generation cTnT (<10 ng/L) but hs-cTnI ≥26 ng/L were at increased risk of cardiovascular death/MI compared to those with hs-cTnI <26 ng/L (9.2% vs 2.9%, P = 0.002). CONCLUSIONS Application of this hs-cTnI assay identified a clinically relevant higher risk of recurrent events among patients with NSTE-ACS, even at very low troponin concentrations.

Funder

Abbott Laboratories

National Institutes of Health

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3