Diagnostic Accuracy and User-Friendliness of 5 Point-of-Care D-Dimer Tests for the Exclusion of Deep Vein Thrombosis

Author:

Geersing Geert-Jan1,Toll Diane B1,Janssen Kristel JM1,Oudega Ruud1,Blikman Marloes JC1,Wijland René1,de Vooght Karen MK2,Hoes Arno W1,Moons Karel GM1

Affiliation:

1. Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht, the Netherlands

2. Department for Clinical Chemistry and Haematology, University Medical Center Utrecht, Utrecht, the Netherlands

Abstract

BACKGROUND Point-of-care D-dimer tests have recently been introduced to enable rapid exclusion of deep venous thrombosis (DVT) without the need to refer a patient for conventional laboratory-based D-dimer testing. Before implementation in practice, however, the diagnostic accuracy of each test should be validated. METHODS We analyzed data of 577 prospectively identified consecutive primary care patients suspected to have DVT, who underwent 5 point-of-care D-dimer tests—4 quantitative (Vidas®, Pathfast™, Cardiac®, and Triage®) and 1 qualitative (Clearview Simplify®)—and ultrasonography as the reference method. We evaluated the tests for the accuracy of their measurements and submitted a questionnaire to 20 users to assess the user-friendliness of each test. RESULTS All D-dimer tests showed negative predictive values higher than 98%. Sensitivity was high for all point-of-care tests, with a range of 0.91 (Clearview Simplify) to 0.99 (Vidas). Specificity varied between 0.39 (Pathfast) and 0.64 (Clearview Simplify). The quantitative point-of-care tests showed similar and high discriminative power for DVT, according to calculated areas under the ROC curves (range 0.88–0.89). The quantitative Vidas and Pathfast devices showed limited user-friendliness for primary care, owing to a laborious calibration process and long analyzer warm-up time compared to the Cardiac and Triage. For the qualitative Clearview Simplify assay, no analyzer or calibration was needed, but interpretation of a test result was sometimes difficult because of poor color contrast. CONCLUSIONS Point-of-care D-dimer assays show good and similar diagnostic accuracy. The quantitative Cardiac and Triage and the qualitative Clearview Simplify D-dimer seem most user-friendly for excluding DVT in the doctor's office.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 38 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3