Quality Specifications for the Determination of Copper, Zinc, and Selenium in Human Serum or Plasma: Evaluation of an Approach Based on Biological and Analytical Variation

Author:

Arnaud Josiane1,Weber Jean-Philippe2,Weykamp Cas W3,Parsons Patrick J4,Angerer Jurgen5,Mairiaux Eric6,Mazarrasa Olav7,Valkonen Sinikka8,Menditto Antonio9,Patriarca Marina9,Taylor Andrew10

Affiliation:

1. Département de Biologie Intégrée, Pôle de biologie, CHU de Grenoble, Grenoble, France

2. Centre de Toxicologie, Institut National de Santé Publique du Québec, Québec, QC Canada

3. MCA Laboratory, Queen Beatrix Hospital, The Netherlands

4. Trace Elements Laboratory, Wadsworth Center, New York State Department of Health, Albany, NY

5. Institute of Occupational, Social and Environmental Medicine, University of Erlangen-Nuernberg, Erlangen, Germany

6. Bureau of Quality Assurance, Scientific Institute of Public Health, Brussels, Belgium

7. Higiene Industrial, Centro de Seguridad y Salud en el Trabajo, Santander, Spain

8. Biomonitoring Laboratory, Finnish Institute of Occupational Health, Helsinki, Finland

9. Dipartimento di Sanità Alimentare e Animale, Istituto Superiore di Sanità, Roma, Italy

10. Centre for Clinical Science and Measurement, School of Biomedical and Life Sciences, University of Surrey, Guildford, U.K

Abstract

Abstract Background: Trace element external quality assessment schemes monitor laboratory performance and provide a stimulus for improvement in accuracy. However, monitoring of participant performance varies according to the scheme and can lead to conflicting conclusions. Methods: Quality specifications based on biological intra- and interindividual variability were calculated and compared to those currently used by various trace element external quality assessment schemes for plasma or serum copper, zinc, and selenium concentrations. For this purpose, we evaluated results reported by participating laboratories in different schemes, at key concentrations, using z scores. Results: Minimal quality specifications developed from the biological intra- and interindividual variability were, for Cu, ±0.84 μmol/L or 12% of the assigned target concentration, whichever is greater; for Zn, ±1.20 μmol/L or 15% of the assigned target concentration, whichever is greater; and for Se, ±0.072 μmol/L or 12% of the assigned target concentration, whichever is greater. Reported performance of the participating laboratories depended on analyte, concentration, and the selected quality specification. In addition, the most commonly used methods for the determination of Cu, Zn, and Se may give different results. Conclusions: The proposed minimal quality specifications based on biological variation are generally slightly less stringent than those currently in use, although they do not drastically change the performance evaluation in the different schemes. These specifications are a first step in the harmonization of practices among the schemes and remain to be evaluated.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 34 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Validation of the Randox colorimetric assays for serum copper and zinc;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;2023-10-19

2. Pre-analytical variables influence zinc measurement in blood samples;PLOS ONE;2023-09-15

3. Elektrolyte und ihre Aussagekraft: Kupfer, Zink und Eisen;kleintier konkret;2023-02

4. Pre-analytical variables influence zinc measurement in blood samples;2023-01-14

5. Atomic Spectrometry in Clinical Chemistry;Encyclopedia of Analytical Chemistry;2022-09-15

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3