Serum Total Prolactin and Monomeric Prolactin Reference Intervals Determined by Precipitation with Polyethylene Glycol: Evaluation and Validation on Common ImmunoAssay Platforms

Author:

Beltran Luisa1,Fahie-Wilson Michael N1,McKenna T Joseph2,Kavanagh Lucille2,Smith Thomas P2

Affiliation:

1. Department of Clinical Chemistry, Southend Hospital, Westcliff-on-Sea, Essex SSO ORY, UK

2. Department of Investigative Endocrinology, St. Vincent’s University Hospital, Elm Park, Dublin 4, Ireland

Abstract

Abstract Background: Macroprolactin is an important source of immunoassay interference that commonly leads to misdiagnosis and mismanagement of hyperprolactinemic patients. We used the predominant immunoassay platforms for prolactin to assay serum samples treated with polyethylene glycol (PEG) and establish and validate reference intervals for total and monomeric prolactin. Methods: We used the Architect (Abbott), ADVIA Centaur and Immulite (Siemens Diagnostics), Access (Beckman Coulter), Elecsys (Roche Diagnostics), and AIA (Tosoh) analyzers with samples from healthy males (n = 53) and females (n = 93) to derive parametric reference intervals for total and post-PEG monomeric prolactin. Concentrations of immunoreactive prolactin isoforms in serum samples from healthy individuals were established by gel filtration chromatography (GFC). We then used samples from 22 individuals whose hyperprolactinemia was entirely attributable to macroprolactin and 32 patients with true hyperprolactinemia to compare patient classifications and prolactin concentrations measured by GFC with the newly derived post-PEG reference intervals. Results: Parametric reference intervals for post-PEG prolactin in male and female serum samples, respectively, were (in mIU/L): 61–196, 66–278 (Centaur); 63–245, 75–381 (Elecsys); 70–301, 92–469 (Access); 72–229, 79–347 (Architect); 73–247, 83–383 (AIA); and 78–263, 85–394 (Immulite). Concordance between GFC and immunoassay-specific post-PEG reference intervals was observed in 311 of 324 cases and for 31 of 32 patients with true hyperprolactinemia and 17 of 22 patients with macroprolactinemia. Results leading to misclassification occurred in a few analyzers for 5 macroprolactinemia patient samples with relatively minor increases in post-PEG prolactin (mean 61 mIU/L). Conclusions: Our validated normative reference data for sera pretreated with PEG and analyzed on the most commonly used immunoassay platforms should facilitate the more widespread introduction of macroprolactin screening by clinical laboratories.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 100 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3