Assessment of the Multiple-Biomarker Approach for Diagnosis of Myocardial Infarction in Patients Presenting with Symptoms Suggestive of Acute Coronary Syndrome

Author:

Apple Fred S1,Smith Stephen W2,Pearce Lesly A3,Murakami MaryAnn M1

Affiliation:

1. Departments of Laboratory Medicine and Pathology and

2. Department of Emergency Medicine, Hennepin County Medical Center and University of Minnesota School of Medicine, Minneapolis, MN

3. Biostatistical Consulting, Minot, ND

Abstract

Abstract Background: Cardiac troponin is the preferred biomarker for detecting acute myocardial injury and infarction (MI). We studied whether multiple biomarkers of numerous pathophysiological pathways would increase the diagnostic accuracy for detecting MI. Methods: Seven biomarkers [myeloperoxidase, soluble CD40 ligand, placental growth factor, matrix metalloproteinase 9 (MMP-9), high-sensitivity C-reactive protein (hsCRP), cardiac troponin I (cTnI), N-terminal pro–B-type natriuretic peptide] and estimated glomerular filtration rate were measured in 457 patients presenting on admission with symptoms suggestive of acute coronary syndrome. Twenty-five patients (5.4%) received MI diagnoses. Clinical sensitivities and specificities were evaluated from 99th-percentile reference values. Forward and backward stepwise logistic regression modeling techniques were used to identify biomarkers that were independently predictive of MI. Results: Biomarker sensitivities ranged from 20% to 96%, and specificities ranged from 19% to 89%. MMP-9 had the highest sensitivity, but its specificity was 19%. cTnI demonstrated a sensitivity of 72% (95% CI, 51%–88%) and a specificity of 89% (95% CI, 85%–92%). In multivariate models, cTnI (P < 0.001) and either hsCRP (P = 0.009) or MMP-9 (P = 0.03) were independently predictive of MI. Addition of hsCRP or MMP-9 increased the specificity to 95% (95% CI, 92%–97%) or 91% (95% CI, 88%–94%), respectively, but reduced the sensitivity to 56% (95% CI, 35%–76%) and 68% (95% CI, 47%–85%) relative to cTnI alone. Conclusions: Our findings indicate that the most clinically accurate biomarker for the early diagnosis of MI is the use of cTnI alone, rather than a multiple-biomarker approach, when an analytically robust cardiac troponin assay based on the 99th percentile is used.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3