Newborn Screening for Pompe Disease by Measuring Acid α-Glucosidase Activity Using Tandem Mass Spectrometry

Author:

Dajnoki Angéla12,Mühl Adolf1,Fekete György2,Keutzer Joan3,Orsini Joe4,DeJesus Victor5,Zhang X Kate3,Bodamer Olaf A1

Affiliation:

1. Division of Biochemical and Paediatric Genetics, University Children’s Hospital Vienna, Austria

2. 2nd Department of Paediatrics, Semmelweis University Budapest, Hungary

3. Genzyme Corporation, Framingham, MA

4. Wadsworth Center, New York State Laboratories, Albany, NY

5. Newborn Screening Branch, Centers for Disease Control and Prevention, Atlanta, GA

Abstract

Abstract background: Pompe disease, caused by the deficiency of acid α-glucosidase (GAA), is a lysosomal storage disorder that manifests itself in its most severe form within the first months of life. Early detection by newborn screening is warranted, since prompt initiation of enzyme replacement therapy may improve morbidity and mortality. We evaluated a tandem mass spectrometry (MS/MS) method to measure GAA activity for newborn screening for Pompe disease. methods: We incubated 3.2-mm punches from dried blood spots (DBS) for 22 h with the substrate [7-benzoylamino-heptyl)-{2-[4-(3,4,5-trihydroxy-6-hydroxymethyl-tetrahydro-pyran-2-yloxy)-phenylcarbamoyl]- ethyl}-carbamic acid tert-butyl ester] and internal standard [7-d5-benzoylamino-heptyl)-[2-(4-hydroxy-phenylcarbamoyl)-ethyl]-carbamic acid tertbutyl ester]. We quantified the resulting product and internal standard using MS/MS. We assessed inter- and intrarun imprecision, carryover, stability, and correlation between enzyme activities and hematocrit and punch location and generated a Pompe disease–specific cutoff value using routine newborn screening samples. results: GAA activities in DBS from 29 known Pompe patients were <2 μmol/h/L. GAA activities in routine newborn screening samples were [mean (SD)] 14.7 (7.2) μmol/h/L (n = 10 279, median 13.3, 95% CI 14.46–14.74 μmol/h/L) and in normal adult samples 9.3 (3.3) μmol/h/L (n = 229, median 9, 95% CI 8.88–9.72 μmol/h/L). GAA activity was stable for 28 days between 37 °C and −80 °C. Carryover could not be observed, whereas intrarun and interrun imprecision were <10%. The limit of detection was 0.26 μmol/h/L and limit of quantification 0.35 μmol/h/L. conclusions: The measurement of GAA activities in dry blood spots using MS/MS is suitable for high-throughput analysis and newborn screening for Pompe disease.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3