Incidence of Undetectable, Measurable, and Increased Cardiac Troponin I Concentrations Above the 99th Percentile Using a High-Sensitivity vs a Contemporary Assay in Patients Presenting to the Emergency Department

Author:

Love Sara A1,Sandoval Yader2,Smith Stephen W3,Nicholson Jennifer4,Cao Jing5,Ler Ranka5,Schulz Karen5,Apple Fred S15

Affiliation:

1. Department of Laboratory Medicine and Pathology, Hennepin County Medical Center, and University of Minnesota, Minneapolis, MN

2. Division of Cardiology, Department of Medicine, Hennepin County Medical Center and Minneapolis Heart Institute, Abbott-Northwestern Hospital, Minneapolis, MN

3. Department of Emergency Medicine, Hennepin County Medical Center and University of Minnesota, Minneapolis, MN

4. Department of Laboratory Medicine and Pathology, Hennepin County Medical Center, Minneapolis, MN

5. Cardiac Biomarkers Trials Laboratory (CBTL), Minneapolis Medical Research Foundation, Minneapolis, MN

Abstract

Abstract INTRODUCTION We compared the incidence of undetectable [below the limit of detection (LoD)], measurable (LoD to 99th percentile), and increased cardiac troponin I (cTnI) concentrations above the 99th percentile between Abbott high-sensitivity cTnI (hs-cTnI) and contemporary cTnI assays in a US emergency department population. METHODS Patients (n = 2100) presenting to the emergency department who had serial cTnI (0, 3, 6, 9 h) measurements ordered on clinical indication were enrolled. Contemporary cTnI [Abbott Architect used clinically; 99th percentile: 0.030 μg/L (30 ng/L)] and hs-cTnI [Abbott investigational; sex-specific 99th percentiles: female (F) 16 ng/L, male (M) 34 ng/L] assays simultaneously measured fresh EDTA plasma. RESULTS The hs-cTnI assay measured fewer undetectable cTnI concentrations compared to the contemporary cTnI assay across baseline (F: 31% vs 47%, M: 22% vs 40%) and serial (F: 21% vs 46%; M: 19% vs 54%) measurements. Conversely, the proportion of measurable cTnI concentrations was higher using hs-cTnI compared to contemporary cTnI assay across both baseline (F: 46% vs 31%; M: 60% vs 33%) and serial (F: 48% vs 28%; M: 83% vs 40%) measurements. The overall proportion of patients with increased cTnI concentrations above the 99th percentile was not significantly different between the contemporary (31%) and hs-cTnI (26%) assays (P = 0.09). CONCLUSIONS In patients presenting to the emergency department, the use of the Abbott hs-cTnI assay provides clinicians with more numeric cTnI concentrations. This occurs via a shift from results below the LoD to those between the LoD and the 99th percentile and does not increase in the number of cTnI concentrations above the 99th percentile.

Funder

Abbott Laboratories

Minneapolis Medical Research Foundation

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry