Effect of Participating in a Quality Improvement System over Time for Point-of-Care C-Reactive Protein, Glucose, and Hemoglobin Testing

Author:

Bukve Tone1,Stavelin Anne1,Sandberg Sverre123

Affiliation:

1. The Norwegian Quality Improvement of Primary Care Laboratories (Noklus), Haraldsplass Deaconess Hospital, Bergen, Norway

2. Department of Global Health and Primary Care, Faculty of Medicine and Dentistry, University of Bergen, Bergen, Norway

3. Laboratory of Clinical Biochemistry, Haukeland University Hospital, Bergen, Norway

Abstract

Abstract BACKGROUND Users of point-of-care testing (POCT) in Norway participate in a quality improvement system that includes education and guidance in safe laboratory management along with participation in external quality assurance schemes (EQAS). The aim of this study was to identify the effect on the analytical performance of POCT C-reactive protein (CRP), glucose, and hemoglobin (Hb) with the use of a quality improvement system over time and to identify which factors are associated with good performance. METHODS Participants' results from 19 EQAS for CRP, glucose, and Hb from 2006 to 2015 along with information on the instruments used and different practice characteristics were analyzed. Logistic regression analysis was used to evaluate the factors associated with good laboratory performance. An instrument evaluation and comparison for CRP determination was performed by using commutable EQA material. RESULTS The mean number of participants in each EQAS was 2134, 2357, and 2271 for CRP, glucose, and Hb, respectively. The percentage of good participant performances increased gradually whereas that of poor performances decreased with participation in a quality improvement system over 9 years for all 3 analytes. Independent factors associated with good performance were type of instrument, the number of times performing EQA, performing internal QC weekly, performing 10 or more tests weekly, and having laboratory-qualified personnel perform the tests. Considering CRP instrument performance, Afinion and QuikRead exhibited the lowest systematic deviation. CONCLUSIONS The analytical quality of CRP, glucose, and Hb testing is improved by systematic participation in a quality improvement system over time.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Reference19 articles.

1. Point-of-care diagnostics: is this driven by supply or demand?;Huckle;Expert Opin Med Diagn,2010

2. Quality error rates in point-of-care testing;O'Kane;Clin Chem,2011

3. Point-of-care testing (POCT): requirements for quality and competence;International Organization for Standardization (ISO),2005

4. Quality management: approaches to reducing errors at the point of care; approved guideline;CLSI,2001

5. International Federation of Clinical Chemistry. Fundamentals for external quality assessment (EQA). Guidelines for improving analytical quality by establishing and managing EQA schemes. Examples from basic chemistry using limited resources. http://www.ifcc.org/ifccfiles/docs/Fundamentals-for-EQA.pdf (Accessed April 2016).

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3