Trueness Evaluation and Verification of Interassay Agreement of 11 Serum IgA Measuring Systems: Implications for Medical Decisions

Author:

Braga Federica1,Infusino Ilenia1,Frusciante Erika1,Ceriotti Ferruccio2,Panteghini Mauro1

Affiliation:

1. Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy

2. Clinical Laboratory, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy

Abstract

Abstract BACKGROUND To identify an IgA deficiency, the availability of reliable IgA lower reference limits is essential, especially in pediatrics. In this study, we reported the results of an intercomparison study aimed to verify the status of standardization of IgA measurements using 11 commercially available measuring systems (MSs). METHODS After confirming its commutability, the ERM-DA470k/IFCC reference material was used for the trueness evaluation of IgA MSs. Furthermore, the interassay agreement was verified using 18 patient pools. By combining the bias, if any, between the obtained mean of ERM-DA470k/IFCC and its target value and the mean imprecision of MSs with the uncertainty of respective calibrators, we also estimated the mean uncertainty (U) of IgA measurements on clinical samples. RESULTS Although the majority of IgA MSs were sufficiently aligned with each other, the bias against the ERM-DA470k/IFCC target value was unacceptable in 55% of cases. This bias resulted in an excessive U of IgA measurement on clinical samples. Importantly, when the analysis focused on the lower IgA concentrations—typical of children—the situation worsened, with only 4 MSs showing good equivalence. CONCLUSIONS Although the harmonization among most commercially available IgA MSs is good, the implementation of traceability to higher order references is inadequate, especially at concentrations ≤0.7 g/L. This analytical background information needs to be considered carefully when defining traceable reference intervals in the pediatric population.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3