European Concerted Action on Anticoagulation. Quality Assessment of the CoaguChek Mini and TAS PT-NC Point-of-Care Whole-Blood Prothrombin Time Monitors

Author:

Poller Leon1,Keown Michelle1,Chauhan Nikhil1,van den Besselaar Anton M H P2,Tripodi Armando3,Shiach Caroline4,Jespersen Jorgen5

Affiliation:

1. European Concerted Action on Anticoagulation Central Facility, School of Biological Sciences, The University of Manchester, Manchester, United Kingdom

2. Haemostasis and Thrombosis Research Centre, Leiden University Medical Center, Leiden, The Netherlands

3. A Bianchi Bonomi, Haemophilia and Thrombosis Centre, IRCCS Maggiore Hospital, University of Milan, Milan, Italy

4. Department of Haematology, Manchester Royal Infirmary, Oxford Road, Manchester, United Kingdom

5. Department for Thrombosis Research, University of Southern Denmark and Department of Clinical Biochemistry, Ribe County Hospital, Esbjerg, Denmark

Abstract

Abstract Background: International Normalized Ratios (INRs) for prothrombin time obtained with the CoaguChek Mini and TAS (RapidPointCoag) PT-NC systems are markedly different and also differ from the “true” INR. There is therefore a need for local quality assessment (QA) of the two systems. Methods: A set of 60 lyophilized artificially depleted and 60 lyophilized coumarin plasmas were tested at 10 centers on both point-of-care testing monitors. Subsets of three and five plasmas were selected as QA plasmas and compared with the remaining 55 to assess the relative ability of the systems to characterize performance at the individual centers. The incidence of aberrant results (outliers; >15% deviation from the true INR) was also recorded. The expected incidence with the QA plasmas was calculated and compared. Results: On both systems, INR with the common sets of 55 lyophilized plasmas varied considerably between centers. With the TAS PT-NC, subsets of five and three European Concerted Action on Anticoagulation (ECAA) artificially depleted plasmas gave good correlation with the 55 plasmas, but the coumarin plasmas performed less well. With the CoaguChek Mini, correlation was good with sets of five artificially depleted QA plasmas and reasonable with three but was less satisfactory with the coumarin plasmas. Outliers were detected with both types of plasmas on both test systems but with variable success. Conclusions: With the TAS PT-NC, three ECAA artificially depleted lyophilized plasmas provided reliable QA, but five lyophilized coumarin plasmas were required. With the CoaguChek Mini, five artificially depleted plasmas gave reliable QA but coumarin plasmas gave poorer results. ECAA QA plasmas provide a local system for checking INRs obtained with monitors of both types.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3