Simultaneous Measurement of 25 Inflammatory Markers and Neurotrophins in Neonatal Dried Blood Spots by Immunoassay with xMAP Technology

Author:

Skogstrand Kristin12,Thorsen Poul2,Nørgaard-Pedersen Bent1,Schendel Diana E3,Sørensen Line C4,Hougaard David M1

Affiliation:

1. Department of Clinical Biochemistry, Statens Serum Institut, Copenhagen, Denmark

2. NANEA at Department of Epidemiology and Social Medicine, Aarhus University, Aarhus, Denmark

3. National Center on Birth Defects and Developmental Disabilities, Centers for Disease Control and Prevention, Atlanta, GA

4. Department of Pediatrics, Copenhagen University Hospital, Hvidovre, Denmark

Abstract

Abstract Background: Inflammatory reactions and other events in early life may be part of the etiology of late-onset diseases, including cerebral palsy, autism, and type 1 diabetes. Most neonatal screening programs for congenital disorders are based on analysis of dried blood spot samples (DBSS), and stored residual DBSS constitute a valuable resource for research into the etiology of these diseases. The small amount of blood available, however, limits the number of analytes that can be determined by traditional immunoassay methodologies. Methods: We used new multiplexed sandwich immunoassays based on flowmetric Luminex® xMAP technology to measure inflammatory markers and neutrophins in DBSS. Results: The high-capacity 25-plex multianalyte method measured 23 inflammatory and trophic cytokines, triggering receptor expressed on myeloid cells-1 (TREM-1), and C-reactive protein in two 3.2-mm punches from DBSS. It also measured 26 cytokines and TREM-1 in serum. Standards Recovery in the 25-plex method were 90%–161% (mean, 105%). The low end of the working range for all 25 analytes covered concentrations found in DBSS from healthy newborns. Mean recovery of exogenous analytes added at physiologic concentrations in DBSS models was 174%, mean intra- and interassay CVs were 6.2% and 16%, respectively, and the mean correlation between added and measured analytes was r2 = 0.91. In DBSS routinely collected on days 5–7 from 8 newborns with documented inflammatory reactions at birth, the method detected significantly changed concentrations of inflammatory cytokines. Measurements on DBSS stored at −24 °C for >20 years showed that most cytokines are detectable in equal concentrations over time. Conclusions: The method can reliably measure 25 inflammatory markers and growth factors in DBSS. It has a large potential for high-capacity analysis of DBSS in epidemiologic case–control studies and, with further refinements, in neonatal screening.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 242 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3