Separation of β2-Transferrin by Denaturing Gel Electrophoresis to Detect Cerebrospinal Fluid in Ear and Nasal Fluids

Author:

Görögh Tibor1,Rudolph Pierre2,Meyer Jens Eduard1,Werner Jochen A3,Lippert Burkard M3,Maune Steffen1

Affiliation:

1. Department of Otorhinolaryngology, Head and Neck Surgery, University of Kiel, Kiel, Germany

2. Department of Pathology, University of Zürich, Zürich, Switzerland

3. Department of Otorhinolaryngology, University of Marburg, Marburg, Germany

Abstract

AbstractBackground: Cerebrospinal fluid (CSF) leakage is a critical condition with a substantial risk of meningitis. We investigated the use of transferrin isoform analysis as a diagnostic marker for detection of CSF leakage in fluid samples.Methods: We analyzed 241 samples from patients with CSF leakage, most commonly presenting as otorrhea or rhinorrhea, by sodium dodecyl sulfate–polyacrylamide gel electrophoresis (SDS-PAGE) with subsequent Western blotting and immunostaining for transferrin. Tears, saliva, nasal fluid, and ear secretions (20 samples each) were analyzed in parallel, and normal human serum served as a control in each experiment. We compared the minimum volume of added CSF that could be detected in secretions by our assay with the minimum volume detected by the prostaglandin-D synthase (β-trace) test. CSF was admixed with blood in different proportions to determine the influence of blood contamination on the transferrin pattern.Results: In all CSF samples, β1- and β2-transferrin were present in nearly equal amounts. In tears and ear secretions, β2-transferrin migrated in the gel in the same manner as in CSF, but its concentration was noticeably lower than that of β1-transferrin, a difference that allowed a clear distinction from the transferrin pattern of CSF. In saliva, both transferrin isoforms were also present but could be distinguished from those of other fluids by electrophoretic migration pattern rather than relative concentrations. With the β-trace test, a minimum of 5 μL of CSF was needed for detection, whereas our β2-transferrin assay yielded a signal of comparable intensity with a minimum of 2 μL of CSF.Conclusion: Analysis of the transferrin microheterogeneity pattern by SDS-PAGE for the identification of CSF leakage is a highly sensitive and specific method that merits consideration as a routine technique.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Reference39 articles.

1. Rouah E, Rogers BB, Buffone GJ. Transferrin analysis by immunofixation as an aid in the diagnosis of cerebrospinal fluid otorrhea. Arch Pathol Lab Med1987;111:756-757.

2. Reisinger PWM, Hochstrasser K. The diagnosis of CSF fistulae on the basis of detection of β2 transferrin by polyacrylamide gel electrophoresis and immunoblotting. Clin Chem Clin Biochem1989;27:169-172.

3. Blennow K, Fredman P. Detection of cerebrospinal fluid leakage by isoelectric focusing on polyacrylamide gels with silver staining using the PhastSystem. Acta Neurochir (Wien)1995;136:135-139.

4. Ryall RG, Peacock MK, Simpson DA. Usefulness of β2-transferrin assay in the detection of cerebrospinal fluid leaks following head injury. J Neurosurg1992;77:737-739.

5. Oberascher G, Arrer E. A new method for using fluorescein to demonstrate oto- and rhinoliquorrhea. Arch Otorhinolaryngol1986;243:117-120.