Evaluation of Imprecision for Cardiac Troponin Assays at Low-Range Concentrations

Author:

Panteghini Mauro1,Pagani Franca1,Yeo Kiang-Teck J2,Apple Fred S3,Christenson Robert H4,Dati Francesco5,Mair Johannes6,Ravkilde Jan7,Wu Alan H B8,

Affiliation:

1. Laboratorio Analisi Chimico Cliniche 1, Azienda Ospedaliera ‘Spedali Civili’, 25125 Brescia, Italy

2. Department of Pathology, Dartmouth-Hitchcock Medical Center and Dartmouth Medical School, Lebanon, NH 03756

3. Department of Laboratory Medicine and Pathology, Clinical Laboratories, Hennepin County Medical Center and the University of Minnesota School of Medicine, Minneapolis, MN 55415

4. Department of Pathology, University of Maryland Medical School of Medicine, Baltimore, MD 21201

5. IVD Consulting, D-35041 Marburg, Germany

6. Department of Internal Medicine, Division of Cardiology, University of Innsbruck School of Medicine, 6020 Innsbruck, Austria

7. Department of Cardiology, Aalborg University Hospital, DK-9100 Aalborg, Denmark

8. Clinical Chemistry Laboratory, Hartford Hospital, Hartford, CT 06102

Abstract

Abstract Background: The European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction (MI) has recommended that an increased cardiac troponin should be defined as a measurement above the 99th percentile value of the reference group. A total imprecision (CV) at the decision limit of ≤10% is recommended. However, peer-reviewed data on assay imprecision are lacking. The purpose of this study was to construct the clinically relevant imprecision profiles for each of the commercially available cardiac troponin assays. Pools of human sera containing cardiac troponin concentrations around the MI decision limit were assessed to identify the lowest concentration associated with a 10% CV. Methods: Eight serum pools targeting different concentrations of cardiac troponin (I and T) were prepared and stored at −70 °C until usage. The cardiac troponin measurement protocol consisted of two replicates per specimen per run, and one run per day for 20 days, using two reagent lots and three calibrations. Manufacturers of each cardiac troponin assay directly performed the measurements. Data analysis for each assay was centralized and performed according to the NCCLS EP5-A guideline. Results: The lowest concentrations (μg/L) providing a 10% CV were as follows: AxSYM, 1.22; ACS:180, 0.37; Centaur, 0.33; Immuno 1, 0.34; Access, 0.06; Vidas, 0.36; Liaison, 0.065; Dimension, 0.26; Opus, 0.90; Stratus CS, 0.10; Immulite, 0.32; Vitros ECi, 0.44; Elecsys, 0.04; AIA 21, 0.09. Conclusion: No cardiac troponin assay was able to achieve the 10% CV recommendation at the 99th percentile reference limit defined by the manufacturer.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3