Improved HPLC Method for Carbohydrate-deficient Transferrin in Serum

Author:

Helander Anders1,Husa Asgeir2,Jeppsson Jan-Olof3

Affiliation:

1. Departments of Clinical Neuroscience and Clinical Chemistry, Karolinska Institutet and Hospital, SE-171 76 Stockholm, Sweden

2. Axis-Shield ASA, N-0510 Oslo, Norway

3. Department of Clinical Chemistry, Malmo University Hospital, SE-205 02 Malmo, Sweden

Abstract

Abstract Background: There is need for a reference method for transferrin glycoforms in serum to which routine immunologic methods for the alcohol marker carbohydrate-deficient transferrin (CDT) can be traceable. We describe an improved HPLC method for transferrin glycoforms. Methods: Transferrin was iron-saturated by mixing the serum with ferric nitrilotriacetic acid, and lipoproteins were precipitated with dextran sulfate and calcium chloride. Separation of glycoforms was performed on a SOURCE 15Q anion-exchange column using salt gradient elution. Quantification relied on selective absorbance of the iron–transferrin complex at 470 nm. The relative amount of each glycoform was calculated as a percentage of the area under the curve, using baseline integration. Results: The HPLC system provided reproducible separation and quantification of the asialo-, monosialo-, disialo-, trisialo-, tetrasialo-, pentasialo-, and hexasialotransferrin glycoforms. Most importantly, disialo- and trisialotransferrin were almost baseline separated. The intra- and interassay CV for disialotransferrin were <5%. Serum and the pretreated samples were stable for at least 2 days at 22 or 4 °C. Sera from 132 healthy controls contained [mean (SD)] 1.16 (0.25)% disialotransferrin, 4.77 (1.36)% trisialotransferrin, 80.18 (2.01)% tetrasialotransferrin, and 13.88 (1.69)% pentasialo- + hexasialotransferrin. In some cases of a high (>6%) trisialotransferrin, monosialotransferrin was detected at <0.25%. Asialotransferrin was not detected in control sera, but was detected in 57% of chronic heavy drinkers and in 62% of sera with ≥2% disialotransferrin. Conclusions: The HPLC method fulfills the requirements of a preliminary reference method for CDT and should work for any combination of serum transferrin glycoforms. This method could also be useful for confirming positive CDT results by immunoassays in medico-legal cases.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3