Atherosclerosis Risk in Communities (ARIC) Carotid MRI Flow Cytometry Study of Monocyte and Platelet Markers: Intraindividual Variability and Reliability

Author:

Catellier Diane J1,Aleksic Nena2,Folsom Aaron R3,Boerwinkle Eric4

Affiliation:

1. Collaborative Studies Coordinating Center, University of North Carolina at Chapel Hill, Department of Biostatistics, Chapel Hill, NC

2. University of Texas Health Science Center at Houston, Division of Hematology and Vascular Biology Research Center, Houston, TX

3. University of Minnesota, School of Public Health, Division of Epidemiology and Community Health, Minneapolis, MN

4. University of Texas Health Science Center at Houston, Human Genetics Center and Institute for Molecular Medicine, Houston, TX

Abstract

Abstract Background: Cellular markers help identify different components of a pathological process and may contribute to the diagnosis, prognostic assessment, and management of patients with suspected syndromes. Flow cytometry can be used to accurately assess markers of platelet and leukocyte activation and cellular aggregation in whole blood. To use cell markers as predictors of disease requires that they be measured reliably and show modest within-individual, day-to-day variation. Methods: We used whole blood flow cytometry to analyze monocyte and platelet markers in the Atherosclerosis Risk in Communities (ARIC) Carotid MRI study. We estimated laboratory variability using 20 split samples, process variation using replicate blood tubes taken from 112 subjects, and biologic plus process variation using replicate blood samples taken 4–8 weeks apart from 55 people. Results: For most analytes, the laboratory CV was <10% (mean 3.6%, range 0%–14.5%) and reliability was excellent (75% of analytes had R > 0.90). Reliability coefficients based on repeat-visit data indicated substantial to high repeatability (R > 0.60) for CD14, Toll-like receptor (TLR)-2, CD162, CD61, CD41, CD62P, CD154, and platelet–leukocyte aggregates. In contrast, TLR-4, CD45, myeloperoxidase (MPO), and cyclooxygenase (COX)-2 had slight to moderate repeat visit reliability. Conclusions: The high repeatability results for selected platelet and monocyte markers indicate that they can be reliably measured in multicenter studies with delayed sample processing, provided that rigorous standardization of sample collection, shipping, and flow cytometry procedures is applied.

Funder

National Heart, Lung, and Blood Institute

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3