Autoantibodies to Cardiac Troponin Associate with Higher Initial Concentrations and Longer Release of Troponin I in Acute Coronary Syndrome Patients

Author:

Pettersson Kim1,Eriksson Susann2,Wittfooth Saara1,Engström Emilia1,Nieminen Markku3,Sinisalo Juha3

Affiliation:

1. Department of Biotechnology, University of Turku, Turku, Finland

2. Innotrac Diagnostics Oy, Turku, Finland

3. Division of Cardiology, Cardiovascular Laboratory, Helsinki University Central Hospital, Helsinki, Finland

Abstract

Abstract Background: Cardiac troponin (cTn) is an established marker of myocardial infarction. Pronounced heterogeneity and the minute amounts released into the circulation constitute significant challenges for cTn detection. Recently, autoantibody formation to cTn was shown to be common and to interfere with immunoassay performance. In this study, we investigated cTn autoantibodies and cardiac troponin I (cTnI) in acute coronary syndrome (ACS) patients over a 1-year period after the index event. Methods: We used a second-generation cTnI assay designed to reduce the interference of cTn autoantibodies. The assay for cTn autoantibodies used 2 anti-cTnI antibodies to capture the ternary cTnI-complex, enabling unrestricted binding of the autoantibodies, which were detected with a labeled antihuman IgG antibody. We analyzed serum samples from 81 non–ST-elevation ACS patients taken at admission and after 1 week and 3 and 12 months. Results: We found 14 cTn autoantibody–positive patients (21%) among the 67 cTnI-positive and none among the 14 cTnI-negative patients. Nine were autoantibody-positive at admission, and 5 became positive at 1 week. Autoantibody signals significantly increased in the 1-week and 3-month samples. At all time points, cTnI was significantly increased in the autoantibody-positive group relative to the negative group. Persistent cTnI elevations at 3 and 12 months were seen in the patients already autoantibody positive at admission. Conclusions: During ACS, patients with cTn autoantibodies have higher cTnI release and therefore larger myocardial damage than patients without autoantibodies. Their cTnI release also lasts longer, at least months. The possible prognostic impact of these observations must be evaluated in larger clinical cohorts.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3