Catecholamine Interference in Enzymatic Creatinine Assays

Author:

Saenger Amy K1,Lockwood Christina2,Snozek Christine L1,Milz Thomas C1,Karon Brad S1,Scott Mitchell G2,Jaffe Allan S13

Affiliation:

1. Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota

2. Department of Laboratory Medicine and Pathology, Washington University School of Medicine, St. Louis, Missouri

3. Cardiovascular Division, Department of Medicine, Mayo Clinic, Rochester, Minnesota

Abstract

Abstract Background: Enzymatic creatinine assays are routinely used in clinical laboratories to provide more accurate estimated glomerular filtration rates and to avoid a perceived lack of analytical specificity associated with picrate (Jaffe) methods. Negative interferences with the enzymatic creatinine assay, which we noted in several patients on dopamine or dobutamine, prompted our further investigation into interference of catecholamines with enzymatic methods. Methods: Spiked solutions of dopamine, dobutamine, epinephrine, and norepinephrine were added to pooled sera at catecholamine concentrations consistent with clinically relevant dosing. Creatinine was measured enzymatically on the Roche P-Modular, Ortho Clinical Diagnostics Vitros 350, and Abbott i-STAT. Jaffe methods were performed on the Roche P-Modular and Siemens Dimension RxL. In 10 patients receiving dopamine and/or dobutamine via a venous or arterial line we evaluated and compared the extent of in vivo creatinine interference in paired serum samples obtained by venipuncture and from indwelling catheters. Results: All catecholamines caused significant negative interference with the Roche enzymatic creatinine assay, most pronounced for dopamine and dobutamine. The Vitros enzymatic assay demonstrated slight negative interferences, and i-STAT enzymatic and Jaffe methods were unaffected by the presence of catecholamines. Significant (P < 0.001) differences in creatinine concentrations by Roche enzymatic vs Jaffe methods were observed in venipuncture specimens compared with arterial or venous catheter specimens, suggesting dopamine and dobutamine reversibly adhere to the catheter lumen. Conclusions: Negative interferences were pronounced for Roche enzymatic results in blood samples obtained from indwelling catheters, a phenomenon not observed in peripheral draws. Physicians and laboratorians should be alert to the possibility of a falsely low creatinine result and reevaluate questionable samples using a method unaffected by catecholamines.

Funder

Siemens

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司