Comprehensive Assessment of M-Proteins Using Nanobody Enrichment Coupled to MALDI-TOF Mass Spectrometry

Author:

Mills John R1,Kohlhagen Mindy C1,Dasari Surendra2,Vanderboom Patrick M3,Kyle Robert A4,Katzmann Jerry A1,Willrich Maria A V1,Barnidge David R1,Dispenzieri Angela4,Murray David L1

Affiliation:

1. Departments of Laboratory Medicine and Pathology

2. Health Sciences Research

3. Medical Genome Facility-Proteomics Core

4. Division of Hematology, Department of Medicine, Mayo Clinic, Rochester, MN

Abstract

Abstract BACKGROUND Electrophoretic separation of serum and urine proteins has played a central role in diagnosing and monitoring plasma cell disorders. Despite limitations in resolution and analytical sensitivity, plus the necessity for adjunct methods, protein gel electrophoresis and immunofixation electrophoresis (IFE) remain front-line tests. METHODS We developed a MALDI mass spectrometry–based assay that was simple to perform, automatable, analytically sensitive, and applicable to analyzing the wide variety of monoclonal proteins (M-proteins) encountered clinically. This assay, called MASS-FIX, used the unique molecular mass signatures of the different Ig isotypes in combination with nanobody immunoenrichment to generate information-rich mass spectra from which M-proteins could be identified, isotyped, and quantified. The performance of MASS-FIX was compared to current gel-based electrophoresis assays. RESULTS MASS-FIX detected all M-proteins that were detectable by urine or serum protein electrophoresis. In serial dilution studies, MASS-FIX was more analytically sensitive than IFE. For patient samples, MASS-FIX provided the same primary isotype information for 98% of serum M-proteins (n = 152) and 95% of urine M-proteins (n = 55). MASS-FIX accurately quantified M-protein to <1 g/dL, with reduced bias as compared to protein electrophoresis. Intraassay and interassay CVs were <20% across all samples having M-protein concentrations >0.045 g/dL, with the ability to detect M-proteins <0.01 g/dL. In addition, MASS-FIX could simultaneously measure κ:λ light chain ratios for IgG, IgA, and IgM. Retrospective serial monitoring of patients with myeloma posttreatment demonstrated that MASS-FIX provided equivalent quantitative information to either protein electrophoresis or the Hevylite™ assay. CONCLUSIONS MASS-FIX can advance how plasma cell disorders are screened, diagnosed, and monitored.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3