Assessing the Quality of Glucose Monitor Studies: A Critical Evaluation of Published Reports

Author:

Mahoney John1,Ellison John2

Affiliation:

1. Departments of Global Product Support and Clinical Research,

2. LifeScan, Inc

Abstract

Abstract Background: In recent years, a large number of studies have been published on the performance of glucose monitors. The quality of these reports is not known. Methods: We searched the PubMed database for performance evaluations of handheld glucose monitors published from August 2002 to November 2006. Relevant articles were compared to 20 recommendations from the Standards for Reporting Diagnostic Accuracy (STARD) and 18 recommendations from the Clinical and Laboratory Standards Institute (CLSI). Results: A total of 52 reports met our inclusion criteria and were reviewed. None (0%) of the reports conformed to all 38 STARD and CLSI recommendations. The range of compliance to these recommendations varied widely (median 53%; range 21%–84%). Only 1 study of the 52 reported following a CLSI recommendation for checking reference test results. Fewer than half (42%) of the reports contained STARD-recommended statements regarding how and when comparative measurements were performed. Conclusions: None of the glucose monitor reports from our review conformed to all STARD and CLSI recommendations. Our finding that the average rate of compliance to recommendations was low suggests that many of the researchers did not follow published recommendations for study design, methodology, and reporting and that study quality and conclusions may have been affected. Future studies evaluating the performance of glucose monitoring systems should be carefully designed and follow published recommendations for methodological and reporting quality.

Funder

LifeScan

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Reference70 articles.

1. Standards of Medical Care in Diabetes. Diabetes Care2006;29(Suppl):S4-42.

2. Gutman S, Bernhardt P, Pinkos A, Moxey-Mims M, Knott T, Cooper J. Regulatory aspects of invasive glucose measurements. Diabetes Technol Ther2002;4:775-777.

3. Review Criteria Assessment of Portable Blood Glucose Monitoring In Vitro Diagnostic Devices Using Glucose Oxidase, Dehydrogenase, or Hexokinase Methodology. HHS Publication FDA-96-604 1996 US Department of Health and Human Services, Public Health Service, Food and Drug Administration, Center for Devices and Radiological Health, Office of Device Evaluation, Division of Clinical Laboratory Services Rockville, MD. .

4. Nichols JH. Interpreting method evaluations. Diabetes Technol Ther2002;4:623-625.

5. Finkielman JD, Oyen LJ, Afessa B. Agreement between bedside blood and plasma glucose measurement in the ICU setting. Chest2005;127:1749-1751.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3