Epitope Specificity and IgG Subclass Distribution of Autoantibodies to Cardiac Troponin

Author:

Savukoski Tanja1,Twarda Aleksandra1,Hellberg Sanna1,Ristiniemi Noora1,Wittfooth Saara1,Sinisalo Juha2,Pettersson Kim1

Affiliation:

1. Department of Biotechnology, University of Turku, Turku, Finland

2. Juha Sinisalo, Division of Cardiology, Helsinki University Central Hospital, Helsinki, Finland

Abstract

BACKGROUND Autoantibodies to cardiac troponins (cTnAAbs) can interfere with the measurement of cardiac troponin I (cTnI) by immunoassays for the diagnosis of myocardial infarction. Therefore, we determined the cTnI binding sites and IgG subclasses of circulating cTnAAbs. METHODS We studied epitope specificity with sandwich-type immunoassays by measuring the recovery of troponin complex added to 10 cTnAAb-negative and 10 cTnAAb-positive sera from healthy volunteers. To study the IgG subclasses, we analyzed admission and 3-month follow-up sera from chest pain patients with a reference assay measuring total IgG (14 cTnAAb negative and 14 cTnAAb positive at 3 months) and with 4 subclass-specific assays measuring exclusively IgG subclasses 1–4. RESULTS Mean recoveries of troponin complex in cTnAAb-positive samples for single cTnI epitopes ranged from 37% to 211%, being lowest for the cTnI midfragment (aa 30–110). However, the lowest sample-specific recoveries, 4%–92%, showed that none of the studied epitopes completely escaped the cTnAAb-related interference. Eight chest pain patients of the cTnAAb-positive group became positive between sampling points, and according to all 5 cTnAAb assays, specific signals were generally higher at follow-up. IgG4, with the highest prevalence, was detected in 68% of samples in the cTnAAb-positive group. CONCLUSIONS IgG subclass studies confirm that cTnAAb formation may be triggered/boosted in acute cardiac events. This new information about the epitope specificity of cTnAAbs should be used to reevaluate existing recommendations regarding use of midfragment epitopes in cTnI assays. To circumvent the negative interference of the highly heterogeneous cTnAAbs, use of 3 or more unconventionally selected epitopes should be considered.

Funder

DIA-NET

Graduate School of Advanced Diagnostic Technologies and Applications

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3