Abstract BACKGROUND Serum prostate-specific antigen (PSA) concentrations after radical prostatectomy typically become undetectable with the use of current immunometric assay methods. Despite modern surgical techniques, 15%–30% of prostate cancer patients undergoing radical prostatectomy develop a biochemical recurrence during follow-up. Unfortunately, poor analytical sensitivity of standard PSA assays delays biochemical recurrence detection, and because of day-to-day assay imprecision ultrasensitive PSA assays cannot assess PSA kinetics. We developed an immuno-PCR assay for total PSA that has a limit of quantification >10 times lower than current ultrasensitive assays. METHODS The 2-site immunometric assay for total PSA employed 2 monoclonal antibodies, one conjugated to a double-stranded DNA label and the other bound to paramagnetic microparticles. After several washing steps, quantification cycles were determined and values were converted to PSA concentrations. We characterized analytical performance and compared accuracy with a commercially available total PSA assay. RESULTS The limit of quantification was 0.65 ng/L and the assay was linear in the range of 0.25–152.0 ng/L. Total imprecision estimates at PSA concentrations of 3.8, 24.1, and 69.1 ng/L were <15.2%, <9.4%, and <10.6%, respectively. Recovery of supplemented PSA ranged from 87.5% to 119.2% (mean 100.3%). Dilution recovery ranged from 96.4% to 115.3% (mean 102.3%). There was no high-dose hook effect up to 50 000 ng/L of PSA. Comparison with the commercial PSA assay showed a regression slope of 1.06 and a correlation coefficient of 0.996. CONCLUSIONS The analytical characteristics of the assay support the use of this assay for the accurate and precise measurement of serum PSA, even at sub–nanogram-per-liter concentrations.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3