Rapid 2nd-Tier Test for Measurement of 3-OH-Propionic and Methylmalonic Acids on Dried Blood Spots: Reducing the False-Positive Rate for Propionylcarnitine during Expanded Newborn Screening by Liquid Chromatography–Tandem Mass Spectrometry

Author:

la Marca Giancarlo1,Malvagia Sabrina1,Pasquini Elisabetta1,Innocenti Marzia2,Donati Maria Alice1,Zammarchi Enrico1

Affiliation:

1. Metabolic Unit, Department of Paediatrics, Meyer Children’s Hospital and

2. Pharmaceuticals Department, University of Florence, Florence, Italy

Abstract

Abstract Background: The expansion of newborn screening programs has increased the number of newborns diagnosed with inborn errors of metabolism in the presymptomatic phase, but it has also increased the number of costly, stress-producing false-positive results. Because propionylcarnitine (C3) is one of the analytes most frequently responsible for false-positive results, we aimed to develop a rapid liquid chromatography–tandem mass spectrometry (LC-MS/MS) method to identify free methylmalonic (MMA) and 3-OH propionic (3OH-PA) acids in blood spots. Methods: We studied newborn screening spots from 250 healthy controls; 124 from infants with abnormal C3, of whom only 5 (4%) were truly affected; 124 from infants with altered isolated methylmalonylcarnitine; and 4 from clinically diagnosed patients. Whole blood was eluted from a 3.2-mm dried blood spot by a CH3CN/H2O 7:3 and 5 mL/L formic. This extract was injected into a LC-MS/MS equipped with pneumatically assisted electrospray without derivatization. Total analysis time was 5 min per sample. Results: The assays were linear up to 3300 nmol/L for both metabolites. Intra- and interassay imprecision data were 3.6%–8% and 3.1%–6%, respectively, for MMA and 5.2%–20% and 3.6%–17% for 3OH-PA. Limit of detection and limit of quantitation were 1.95 and 4.2 μmol/L, respectively, for MMA and 8 and 10 μmol/L for 3OH-PA. The recoveries were 92.9%–106.1%. No deterioration was noted on the columns after 500 chromatographic runs. If the new method had been used as a 2nd-tier test for the 124 samples, only the 5 true positives would have been recalled for additional samples, and the positive predictive value would have been 100%. Conclusions: This method has the potential to markedly reduce false-positive results and the associated costs and anxiety. It may also be suitable for diagnosing and routinely monitoring blood spots for methylmalonic aciduria and propionic acidemia.

Funder

Family Association AMMEC

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3