Comparison of Bromcresol Green and Agarose Protein Electrophoresis for Quantitation of Serum Albumin in Multiple Myeloma

Author:

Snozek Christine LH1,Saenger Amy K1,Greipp Philip R2,Bryant Sandra C3,Kyle Robert A2,Rajkumar S Vincent2,Katzmann Jerry A1

Affiliation:

1. Departments of Laboratory Medicine and Pathology,

2. Internal Medicine/Division of Hematology, and

3. Division of Biostatistics, Mayo Clinic College of Medicine, Rochester, MN

Abstract

Abstract Background: The International Staging System for multiple myeloma has increased the importance of accurate measurement of serum albumin. Two common albumin assays, bromcresol green (BCG) and agarose gel protein electrophoresis (PEL), frequently yield discordant results, creating confusion regarding which assay is superior for use in myeloma. Methods: We measured albumin by BCG on a Roche Modular system, by PEL with a Helena SPIFE SPE Vis agarose gel, and by immunonephelometry performed on a Dade Behring BNII nephelometer. BCG and PEL were used to measure albumin in 5777 patient samples, and all 3 methods were used in an additional 252 samples. The clinical impact was assessed on 698 myeloma patient samples. Results: For sera with zero/low monoclonal immunoglobulin protein (M)-spike (0 to <15 g/L), results for both BCG and PEL correlated well to nephelometry, although median PEL results were 8 g/L lower than corresponding BCG measurements. Correlation between PEL and nephelometry or BCG diminished with increasing M-spike, with PEL eventually overestimating albumin compared with both other assays. IgG and IgA M-spikes showed significantly different effects on albumin discordance. For 35% of myeloma patients, discrepancy between BCG and PEL had a potentially clinically significant effect on staging, but no difference in group survival was found. Conclusions: Both BCG and PEL correlate well to nephelometry in sera with zero/low M-spikes. In the presence of larger M-spikes, PEL correlates poorly to nephelometry or BCG, whereas BCG compares well with nephelometry regardless of M-spike. Thus, albumin measurement can be performed reliably in myeloma patient sera by use of inexpensive, automated BCG assays.

Funder

National Cancer Institute

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 27 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3