Specificity and Clinical Utility of Methods for the Detection of Macroprolactin

Author:

Kavanagh Lucille12,McKenna T Joseph12,Fahie-Wilson Michael N3,Gibney James1,Smith Thomas P1

Affiliation:

1. Department of Investigative Endocrinology, St. Vincent’s University Hospital, Dublin, Ireland

2. The Conway Institute of Biomolecular and Biomedical Research, University College, Dublin, Ireland

3. Department of Clinical Chemistry, Southend Hospital, Essex, United Kingdom

Abstract

Abstract Background: Increased serum concentrations of macroprolactin are a relatively common cause of misdiagnosis and mismanagement of hyperprolactinemic patients. Methods: We studied sera from a cohort of 42 patients whose biochemical hyperprolactinemia was explained entirely by macroprolactin. Using 5 pretreatments, polyethylene glycol (PEG), protein A (PA), protein G (PG), anti-human IgG (anti-hIgG), and ultrafiltration (UF), to deplete macroprolactin from sera before immunoassay, we compared residual prolactin concentrations with monomer concentrations obtained by gel-filtration chromatography (GFC). A monomeric prolactin standard was used to assess recovery and specificity of the pretreatment procedures. Results: Residual prolactin concentrations in all pretreated sera differed significantly (P <0.001) from monomeric concentrations obtained after GFC. PEG underestimated (mean, 75%), whereas PA, PG, anti-hIgG, and UF overestimated (means, 178%, 151%, 178%, and 112%, respectively) the amount of monomer present. Of the 5 methods examined, PEG correlated best with GFC (r = 0.80) followed by PG (r = 0.78), PA (r = 0.72), anti-hIgG (r = 0.70), and UF (r = 0.61). After UF or pretreatment with anti-hIgG or PEG, recovery of monomeric prolactin standard was low: 60%, 85%, and 77% respectively. In contrast, pretreatment with PA or PG gave almost quantitative recovery. Conclusions: None of the methods examined yielded results identical to the GFC method. PEG pretreatment yielded results that correlated best and is recommended as the first-choice alternative to GFC.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 87 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3