Sensitive Nonradiometric Method for Determining Thymidine Kinase 1 Activity

Author:

Öhrvik Anders1,Lindh Maria1,Einarsson Roland1,Grassi Jacques2,Eriksson Staffan3

Affiliation:

1. DiaSorin AB, SE-161 02 Bromma, Sweden

2. CEA, Pharmacology and Immunology Unit, CEA/Saclay, Gif sur Yvette, France

3. Department of Molecular Biosciences, Swedish University of Agricultural Sciences, BMC, Uppsala, Sweden

Abstract

AbstractBackground: Thymidine kinase 1 (TK1) is a cytoplasmic enzyme, produced only in the S-phase of proliferating cells, that has potential as a tumor marker. Specific determination of TK1 in serum is difficult, in part because of differences in the physical properties of serum TK1 compared with cytoplasmic TK1.Methods: The first step in the new assay was phosphorylation of 3′-azido-2′,3′-deoxythymidine (AZT) to AZT 5′-monophosphate (AZTMP) by TK1 present in patient material. The AZTMP formed was measured in a competitive immunoassay with specific anti-AZTMP antibodies and AZTMP-labeled peroxidase. Results were compared with those of a TK radioenzyme assay (REA) for 78 samples from patients suffering from hematologic diseases.Results: The detection limit was 78 μIU/L, and within-run CVs <20% were seen for samples with TK1 down to 130 μIU/L. Cross-determination of the mitochondrial isoenzyme TK2 activity was <0.1%. Between-assay imprecision (CV) was 3.5–7.4%, and the within-assay imprecision was 4.1–9.1%. In studies of recovery and linearity on dilution, measured values ranged from 84% to 115% of expected at concentrations of 0.26–10.4 mIU/L. Results of the new assay (mIU/L) = 0.109 × TK REA (U/L) + 0.092. Heterophilic antibodies did not interfere in the assay. The upper 95th percentile, in 100 healthy individuals, was 0.94 mIU/L, and the median value was 0.43 mIU/L.Conclusion: The TK1 enzyme-labeled immunoassay uses a stable substrate, is precise, appears to be accurate, and is resistant to interferences. It may provide a practical tool in the management of hematologic malignancies.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3