Selected Reaction Monitoring–Mass Spectrometric Immunoassay Responsive to Parathyroid Hormone and Related Variants

Author:

Lopez Mary F1,Rezai Taha1,Sarracino David A1,Prakash Amol1,Krastins Bryan1,Athanas Michael2,Singh Ravinder J3,Barnidge David R3,Oran Paul4,Borges Chad4,Nelson Randall W45

Affiliation:

1. ThermoFisher Scientific BRIMS, Cambridge, MA

2. VAST Scientific, Cambridge, MA

3. Mayo Clinic College of Medicine, Rochester, MN

4. Biodesign Institute, Arizona State University, Tempe, AZ

5. Intrinsic Bioprobes, Tempe, AZ

Abstract

AbstractBackground: Parathyroid hormone (PTH) assays able to distinguish between full-length PTH (PTH1–84) and N-terminally truncated PTH (PTH7–84) are of increasing significance in the accurate diagnosis of endocrine and osteological diseases. We describe the discovery of new N-terminal and C-terminal PTH variants and the development of selected reaction monitoring (SRM)-based immunoassays specifically designed for the detection of full-length PTH [amino acid (aa)1–84] and 2 N-terminal variants, aa7–84 and aa34–84.Methods: Preparation of mass spectrometric immunoassay pipettor tips and MALDI-TOF mass spectrometric analysis were carried out as previously described. We used novel software to develop SRM assays on a triple-quadrupole mass spectrometer. Heavy isotope-labeled versions of target peptides were used as internal standards.Results: Top-down analysis of samples from healthy individuals and renal failure patients revealed numerous PTH variants, including previously unidentified aa28–84, aa48–84, aa34–77, aa37–77, and aa38–77. Quantitative SRM assays were developed for PTH1–84, PTH7–84, and variant aa34–84. Peptides exhibited linear responses (R2 = 0.90–0.99) relative to recombinant human PTH concentration limits of detection for intact PTH of 8 ng/L and limits of quantification of 16–31 ng/L depending on the peptide. Standard error of analysis for all triplicate measurements was 3%–12% for all peptides, with <5% chromatographic drift between replicates. The CVs of integrated areas under the curve for 54 separate measurements of heavy peptides were 5%–9%.Conclusions: Mass spectrometric immunoassays identified new clinical variants of PTH and provided a quantitative assay for these and previously identified forms of PTH.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 117 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3