Simultaneous Phenotyping and Quantification of α-1-Antitrypsin by Liquid Chromatography–Tandem Mass Spectrometry

Author:

Chen Yuhong1,Snyder Melissa R2,Zhu Yi3,Tostrud Linda J2,Benson Linda M3,Katzmann Jerry A24,Bergen H Robert3

Affiliation:

1. Division of Clinical Pharmacology, Department of Molecular and Experimental Therapeutics

2. Division of Clinical Biochemistry & Immunology, Department of Laboratory Medicine & Pathology

3. Mayo Proteomics Research Center, and

4. Division of Hematology, Department of Internal Medicine, Mayo Clinic, Rochester, MN

Abstract

BACKGROUNDα-1-Antitrypsin (A1AT) deficiency results from a genetic disorder at 2 common loci. Diagnosis requires quantification of A1AT and subsequent identification of the specific variant. The current algorithm of laboratory testing for the diagnosis of A1AT deficiency uses a combination of quantification (nephelometry), genotyping, and/or phenotyping. We developed a multiple reaction monitoring liquid chromatography–tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of A1AT and identification of the 2 most common deficiency alleles present in 95% of the patients with A1AT deficiency.METHODSSerum samples (n = 40) were digested with trypsin, and appropriate 13C/15N-labeled standard peptides were added. We performed LC-MS/MS analysis with a 0.5- by 150-mm C18 column and H2O:acetonitrile:n-propanol:formic acid (A:98:1:1:0.2 and B:10:80:10:0.2; flow 12 μL/min) mobile phase in positive ion mode on a TSQ Quantum triple quadrupole MS system. We measured the A1AT concentration by comparison to a calibration curve and determined the phenotype by the presence or absence of variant peptides. We compared the results to the current phenotyping assay by isoelectric focusing (IEF) and the immunonephelometry quantitative assay.RESULTSFor A1AT allele detection, in 39 of 40 samples the LC-MS/MS results were identical to those obtained by IEF gel electrophoresis. The single discrepant result was rerun by IEF at a lower dilution, and the results were in concordance. The A1AT quantification by LC-MS/MS also compared favorably with nephelometry.CONCLUSIONSThe LC-MS/MS method correlates well with current phenotyping and nephelometric assays and has the potential to improve the laboratory diagnosis of genetic A1AT deficiency.

Funder

NIH

Arlene Kogod Center on Aging

Noaber Foundation

Ted Nash Foundation

Mayo Clinic Research Committee

David Woods Kemper Memorial Foundation

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry