Abstract

Abstract Background: Analog-based free testosterone test results, sex hormone binding globulin (SHBG) concentrations, and total testosterone concentrations are somehow related. This study used new experiments to clarify these relationships. Methods: An analog-based free testosterone immunoassay and a total testosterone immunoassay were applied to well-defined fractions of serum testosterone. First, they were applied to the 2 fractions (retentate and dialysate) of normal male serum obtained by equilibrium dialysis. Second, they were applied to covaried concentrations of SHBG and total testosterone. Third, they were applied to decreasing concentrations of SHBG and protein-bound testosterone, offset by increasing concentrations of protein-free testosterone, while total testosterone was held constant. Results: The analog-based free testosterone assay and the total testosterone assay detected and reported serum testosterone test results from serum retentate, whereas neither assay detected the free testosterone in serum dialysate. Test results reported by the analog-based free testosterone assay followed varied concentrations of SHBG and total testosterone. When total testosterone was held constant, however, analog-based free testosterone test results did not follow varied concentrations of serum proteins or of free testosterone. Conclusion: An analog-based free testosterone immunoassay reported free testosterone test results that were related to total testosterone concentrations under varied experimental conditions. This alleged free testosterone assay did not detect serum free testosterone (the test results it reported were nonspecific) and should not be used for this purpose.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 45 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3