Excretion of Methamphetamine and Amphetamine in Human Sweat Following Controlled Oral Methamphetamine Administration

Author:

Barnes Allan J1,Smith Michael L2,Kacinko Sherri L1,Schwilke Eugene W1,Cone Edward J3,Moolchan Eric T1,Huestis Marilyn A1

Affiliation:

1. Chemistry and Drug Metabolism, Intramural Research Program, National Institute on Drug Abuse, National Institutes of Health, Baltimore, MD

2. Division of Forensic Toxicology, Office of the Armed Forces Medical Examiner, Armed Forces Institute of Pathology, Rockville, MD

3. Johns Hopkins School of Medicine, Baltimore, MD

Abstract

Abstract Background: Understanding methamphetamine (MAMP) and amphetamine (AMP) excretion in sweat is important for interpreting sweat and hair testing results in judicial, workplace, and drug treatment settings. Methods: Participants (n = 8) received 4 10-mg (low) oral doses of sustained-release S-(+)-MAMP HCl (d-MAMP HCl) within 1 week in a double-blind, institutional review board–approved study. Five participants also received 4 20-mg (high) doses 3 weeks later. PharmChek sweat patches (n = 682) were worn for periods of 2 h to 1 week during and up to 3 weeks after dosing. The mass of MAMP and AMP in each patch was measured by GC-MS, with a limit of quantification of 2.5 ng/patch. Results: MAMP was measurable in sweat within 2 h of dosing. After low and high doses, 92.9% and 62.5% of weekly sweat patches were positive, with a median (range) MAMP of 63.0 (16.8–175) and 307 (199–607) ng MAMP/patch, respectively; AMP values were 15.5 (6.5–40.5) and 53.8 (34.0–83.4) ng AMP/patch. Patches applied 2 weeks after the drug administration week had no measurable MAMP following the low doses, and only 1 positive result following the high doses. Using criteria proposed by the Substance Abuse Mental Health Services Administration, 85.7% (low) and 62.5% (high) weekly sweat patches from the dosing week were positive for MAMP, and all patches applied after the dosing week were negative. Conclusions: These data characterize the excretion of MAMP and AMP after controlled MAMP administration and provide a framework for interpretation of MAMP sweat test results in clinical and forensic settings.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3