Numeric Definition of the Clinical Performance of the Nested Reverse Transcription-PCR for Detection of Hematogenous Epithelial Cells and Correction for Specific mRNA of Non-Target Cell Origin as Evaluated for Prostate Cancer Cells

Author:

Schamhart Denis1,Swinnen Johannes2,Kurth Karl-Heinz1,Westerhof Alex1,Kusters Ron3,Borchers Holger4,Sternberg Cora5

Affiliation:

1. Department of Urology, Academic Medical Center, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands

2. LEGENDO, University of Leuven, B-3000 Leuven, Belgium

3. Hieronymus Bosch Hospital (Jeroen Bosch Ziekenhuis), 5211 NL Den Bosch, The Netherlands

4. Department of Urology, University of Aachen, D-52057 Aachen, Germany

5. Foundation Vincenzo Pansadoro, 00165 Rome, Italy

Abstract

Abstract Background: Inappropriate quality management of reverse transcription-PCR (RT-PCR) assays for the detection of blood-borne prostate cancer (PCa) cells hampers clinical conclusions. Improvement of the RT-PCR methodology for prostate-specific antigen (PSA) mRNA should focus on an appropriate numeric definition of the performance of the assay and correction for PSA mRNA that is not associated with PCa cells. Methods and Results: Repeated (RT-)PCR tests for PSA mRNA in single blood specimens from PCa patients and PCa-free controls, performed by four international institutions, showed a large percentage (≈50%) of divergent test results. The best estimates of the mean, λ (SD), of the expected Poisson frequency distributions of the number of positive tests among five replicate assays of samples from PCa-free individuals were 1.0 (0.2) for 2 × 35 PCR cycles and 0.2 (0.1) for 2 × 25 PCR cycles. Assessment of the numeric value of the mean can be considered as a new indicator of the performance of a RT-PCR assay for PSA mRNA under clinical conditions. Moreover, it determines the required number of positive test repetitions to differentiate between true and false positives for circulating prostate cells. At a predefined diagnostic specificity of ≥98%, repeated PCRs with λ of either 1.0 or 0.2 require, respectively, more than three or more than one positive tests to support the conclusion that PSA mRNA-containing cells are present. Conclusions: Repeated nested PCR tests for PSA and appropriate handling of the data allow numeric quantification of the performance of the assay and differentiation between analytical false and true positives at a predefined accuracy. This new approach may contribute to introduction of PSA RT-PCR assays in clinical practice.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3