Analytical and Clinical Validation of Two Commercially Available Immunoassays Used in the Detection of TSHR Antibodies

Author:

Kemble David J12,Jackson Tara12,Morrison Mike12,Cervinski Mark A12,Nerenz Robert D1

Affiliation:

1. Department of Pathology and Laboratory Medicine, Dartmouth-Hitchcock Medical Center, Lebanon, NH

2. The Geisel School of Medicine at Dartmouth, Hanover, NH

Abstract

Abstract Background Graves disease is caused by autoantibodies that target the thyroid-stimulating hormone receptor (TSHR). Anti-TSHR autoantibody measurement is routinely performed to differentiate between Graves disease and other causes of hyperthyroidism. We evaluated the clinical performance of a reference laboratory bioassay [the Thyretain thyroid-stimulating immunoglobulin (TSI) Bioassay by Diagnostic Hybrids] and 2 commercially available immunoassays: the TSI Bridge immunoassay by Siemens and the thyroid-stimulating hormone receptor antibody (TRAb) immunoassay by Roche. We further evaluated the analytical performance of the Siemens TSI and Roche TRAb assays. Methods We performed method comparisons using 125 patient specimens submitted for TSI testing for clinical purposes. Concordance of patient results was assessed between the 3 methods, and chart review was performed to further evaluate samples that generated discordant results. All 3 methods were also evaluated for potential interference caused by human chorionic gonadotropin (hCG). Results The Roche and Siemens assays demonstrated acceptable day-to-day precision, within-run precision, and precision at the clinical decision cutoffs. Despite manufacturer-defined analytical measuring ranges up to 40 IU/L, the Roche and Siemens assays were linear to 20 IU/L and 15 IU/L, respectively. hCG concentrations up to 150000 IU/L did not interfere with any of the methods evaluated. Moderate agreement between methods was observed when testing patient specimens that generated negative (≤1.3) or weakly positive (1.4–3.8) results by the Thyretain assay. One hundred percent agreement was observed when the Thyretain assay was strongly positive (≥3.9). Conclusions The 3 commercially available anti-TSHR autoantibody measurement methods demonstrated equivalent performance in patients with untreated Graves disease. Discordant results were observed when testing specimens collected from patients undergoing treatment for Graves disease. In these patients, the Siemens TSI assay more frequently generated results consistent with clinical history, results of other laboratory tests, and imaging studies than the Thyretain Bioassay and Roche TRAb assay.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Reference15 articles.

1. Diagnosis and management of Graves disease: a global overview;Bartalena;Nat Rev Endocrinol,2013

2. Hyperthyroidism;De Leo;Lancet,2016

3. Hyperthyroidism: diagnosis and treatment;Kravets;Am Fam Physician,2016

4. Thyroid stimulating immunoglobulin (TSI) in Graves' disease;Ochi;Endocr J,1998

5. Fetal and neonatal hyperthyroidism and hypothyroidism due to maternal TSH receptor antibodies;McKenzie;Thyroid,1992

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3