Method Performance of Bicarbonate and Electrolytes by Use of Duodenal Fluid for Assessment of Exocrine Pancreatic Function

Author:

Pyle-Eilola Amy1,Pagan Jill2,Kayatin Adam2,Povse Patrick N2,Rietschlin Jacqua A2,Cotten Steven W3

Affiliation:

1. Department of Pathology and Laboratory Medicine, Nationwide Children's Hospital, Columbus, OH

2. Department of Pathology, Ohio State University Wexner Medical Center, Columbus, OH

3. Department of Pathology and Laboratory Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC

Abstract

Abstract Background Evaluation of exocrine pancreatic insufficiency is challenging for both clinicians and laboratories. Indirect pancreatic function tests such as serum trypsinogen, fecal elastase, and fecal fat measurements are moderately sensitive for diagnosis of advanced chronic pancreatitis but show reduced sensitivity and specificity for diagnosis of early disease. An alternative is the endoscopic pancreatic function test, which uses duodenal secretions after administration of IV secretin. Samples are collected at various times via the endoscopic tube and then analyzed for bicarbonate, sodium, potassium, and chloride. Methods Precision, linearity, method comparison, and stability studies were performed on the Beckman Coulter AU5822 chemistry analyzer with duodenal fluid. Comparison with the Vitros 4600 dry slide chemistry instrument was used to interrogate differences between methods. Results All assays produced a CV <2% without any measurable effects from the endoscopy fluid matrix and showed acceptable imprecision near the limit of detection (CV < 5%). All analytes showed linear dilution across the analytical measuring range. All the calculated error biases from dilutions were within 50% of the CLIA-allowable error for serum for each of the respective analytes. The calculated slopes ranged from 0.841 to 1.274 when compared to the Vitros 4600. Stability studies demonstrated that sodium, potassium, chloride, and bicarbonate remained stable after storage at −20 °C and after multiple freeze–thaw cycles. The percent change for all analytes was <5% mmol/L. Conclusions The AU5800 series demonstrated adequate performance for the analysis of bicarbonate in duodenal fluid and therefore can be used for assessment of exocrine pancreatic function. However, notable discrepancies were observed for sodium, potassium, and chloride between the AU5800 series and the Vitros 4600.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. A Review of Current Practices and Future Trends in Body Fluid Testing;The Journal of Applied Laboratory Medicine;2023-05-19

2. Evaluation of exocrine pancreatic function;Contemporary Practice in Clinical Chemistry;2020

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3