Affiliation:
1. Department of Pathology, University of Chicago, Chicago, IL
Abstract
Abstract
Background
Recently, the US Food and Drug Administration cleared 3 nucleic acid amplification test (NAAT) assays for detection of Streptococcus pyogenes [group A Streptococcus (GAS)] in pharyngeal specimens. However, there are limited studies evaluating the performance of these NAAT assays.
Methods
We compared the results of 3 NAATs (cobas Liat, Luminex Aries, and Cepheid Xpert Xpress) and a rapid antigen assay (Quidel QuickVue in-line strep A) with the accepted gold standard method, bacterial culture.
Results
Sixty-eight throat swab specimens collected between August and October 2017 were tested. Compared to bacterial culture, the sensitivities, specificities, positive predictive value, and negative predictive value for detecting GAS were as follows: cobas Liat: 100%, 97.4%, 96.7%, and 100%; Cepheid Xpert: 100%, 97.4%, 96.7%, and 100%; Luminex Aries: 95.2%, 100%, 100%, and 95.5%. The Quidel QuickVue in-line strep A assay showed poor sensitivity, detecting only 5.2% of culture-positive specimens.
Conclusion
The 3 NAATs have high sensitivity when compared with bacterial culture for detection of GAS. With rapid turnaround time and ease of use, these tests can be considered as reliable point-of-care tests for the diagnosis of GAS, replacing the need for back-up culture.
Publisher
Oxford University Press (OUP)
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献