An HPLC Ultraviolet Method Using Low Sample Volume and Protein Precipitation for the Measurement of Retinol in Human Serum Suitable for Laboratories in Low- and Middle-Income Countries

Author:

Chaudhary-Webb Madhulika1,Schleicher Rosemary L1,Erhardt Juergen G2,Pendergrast Elizabeth C3,Pfeiffer Christine M1

Affiliation:

1. Centers for Disease Control and Prevention, Atlanta, GA

2. SEAMEO, Jakarta, Indonesia

3. Battelle, Atlanta, GA

Abstract

Abstract Background Assessing vitamin A status in populations remains a high public health priority for low- and middle-income countries. However, analytical difficulties with serum retinol measurements persist in international laboratories. Nearly all participants in a Centers for Disease Control and Prevention external quality assessment program use HPLC to measure serum retinol, but round-to-round results failing to meet acceptable criteria suggest the need to provide a straightforward stable HPLC ultraviolet (UV) method that can be adopted by these laboratories to improve performance. We present a protein precipitation HPLC-UV method that measures serum retinol below the deficiency cutoff value (<0.7 μmol/L or 20 μg/dL) that is suitable for low- and middle-income countries and uses commercially available materials. Methods Serum (25 μL) added to retinyl acetate was precipitated with acetonitrile (125 μL) to extract retinol. Solvent-based calibration solutions required no extraction. Calibration used either single-point (50 μg/dL) or multipoint solutions (0.52–100 μg/dL). C18 column (4.6 × 100 mm) and acetonitrile with 0.1% triethylamine/water (83/17, v/v) as isocratic mobile phase (1.1 mL/min), achieved baseline separation (7 minutes). Results With only 25 μL of serum, the limit of detection was 0.52 μg/dL. Single- and multipoint calibration generated equivalent results. Over several years, between-run imprecision was ≤7.1% in multiple quality-control materials. Overall mean (CV) method bias for NIST-certified reference materials (e-series) was −0.2% (5.8%). Maximally, 180 samples were processed within 24 h. Conclusions This method was robust and stable over years and accurately measured serum retinol with low-volume samples. Thus, it may be of interest to low- and middle-income countries and to pediatric and finger stick applications.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Reference20 articles.

1. UNICEF. Nepal National Micronutrient Status Survey—2016. https://www.unicef.org/nepal/media/1206/file (Accessed February 2019).

2. Uganda Bureau of Statistics. Uganda Demographic and Health Survey 2016. http://www.ubos.org/onlinefiles/uploads/ubos/pdf%20documents/Uganda_DHS_2016_KIR.pdf (Accessed February 2019).

3. National Statistical Office. Malawi Micronutrient Survey Key Indicators Report 2015–16. https://dhsprogram.com/pubs/pdf/FR319/FR319m.pdf (Accessed February 2019).

4. Serum retinol concentrations for determining the prevalence of vitamin A deficiency in populations. WHO/NMH/NHD/MNM/11.3;World Health Organization,2011

5. Biomarkers of nutrition for development (BOND)-vitamin A review;Tanumihardjo;J Nutr,2016

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3