Affiliation:
1. Departments of Pathology and Molecular Medicine, McMaster University, Hamilton, Canada
2. Department of Emergency Medicine, University of Calgary, Calgary, Alberta
3. Division of Emergency Medicine, McMaster University, Hamilton, Canada
Abstract
Abstract
Background
Studies have illustrated how a low or undetectable high-sensitivity cardiac troponin (hs-cTn) concentration at emergency department (ED) presentation can rule out myocardial infarction (MI). A problem with using an undetectable hs-cTn cutoff is that this value may be defined differently among hospitals and is also difficult to monitor. In the present study, we assess the diagnostic performance of a clinical chemistry score (CCS) vs hs-cTn alone in the presentation blood sample in the ED for patient hospital admission in a multicenter setting.
Methods
From January 1 to June 30, 2018, consecutive patients with random glucose, creatinine (for an estimated glomerular filtration rate calculation), and hs-cTnI (Abbott, 2 hospitals, Hamilton, Ontario, n = 10496) or hs-cTnT (Roche, 4 hospitals, Calgary, Alberta, n = 25177) were assessed for hospital admission with the CCS (range of scores, 0–5) or hs-cTn alone. Sensitivity, specificity, predicative values, and likelihood ratios were calculated for a CCS of 0 and 5 and for hs-cTn alone (hs-cTnI cutoffs, 5 and 26 ng/L; hs-cTnT cutoffs, 6 and 14 ng/L).
Results
The CCS of 0 (CCS <1) identified approximately 10% of all patients as low risk and had a sensitivity for hospital admission of nearly 98% as compared to <93% when hs-cTnT (<6 ng/L) or hs-cTnI (<5 ng/L) cutoffs alone were used. A CCS ≥5 had a specificity for hospital admission >95%, with approximately 14% of patients at high risk.
Conclusions
An ED disposition (admit or send home) using the presentation blood sample could occur in nearly 25% of all patients by use of the CCS.