Abstract

Abstract Background The development of more efficient drug delivery devices for ciclesonide inhalation products requires an ultrasensitive bioanalytical method to measure systematic exposure of ciclesonide (CIC) and its active metabolite desisobutyryl-ciclesonide (des-CIC) in humans. Method Serum sample was extracted with 1-chlorobutane. A reversed-phase liquid chromatography coupled with atmospheric pressure photoionization–tandem mass spectrometry (LC-APPI-MS/MS) method was used for quantification of 1–500 pg/mL for both analytes in a 0.500-mL serum. The analysis time was 4.7 min/injection. CIC-d11 and des-CIC-d11 were used as the internal standards. Results Calibration curves showed good linearity (r2 > 0.99) for both analytes. This novel method was precise and accurate with interassay precision and accuracy of all within 9.6% CV and ± 4.0% bias for regular QC samples. Extraction recovery was approximately 85% for both analytes. Serum samples are stable for 3 freeze–thaw cycles, 24 h at bench top, and up to 706 days at both −20 °C and −70 °C. This method was successfully used to support a pharmacokinetic (PK) comparison between the inhalation suspensions and an inhalation aerosol of ciclesonide in healthy participants. The method robustness was also supported by the good incurred sample reanalysis reproducibility. Conclusion APPI, a highly selective and sensitive ionization source, made possible for quantifying CIC and des-CIC with a lower limit of quantification (LLOQ) of 1 pg/mL in human serum by LC-MS/MS. A 10-fold sensitivity improvement from the most sensitive reported method (LLOQ, 10 pg/mL) is essential to fully characterize the PK profiles of CIC and des-CIC in support of the clinical development of the ciclesonide-related medications for patients.

Funder

Sunovion Pharmaceuticals, Inc

Publisher

Oxford University Press (OUP)

Subject

General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3