Variation in the use of intensity-modulated radiation therapy (IMRT) in the state of Michigan: 2005-2010.

Author:

Hayman James1,Griffith Kent A.2,Jagsi Reshma1,Feng Mary Uan-Sian1,Moran Jean M.1,Piotrowski Tania L.1,Pierce Lori J.1

Affiliation:

1. Department of Radiation Oncology, University of Michigan Health System, Ann Arbor, MI

2. University of Michigan Comprehensive Cancer Center, Ann Arbor, MI

Abstract

219 Background: Interest is growing in value in health care, defined as better outcomes at lower costs. A primary driver of cost in radiation oncology is the use of IMRT. We examined the patterns and correlates of use of IMRT across Michigan using publicly available data. Methods: As a certificate of need state, Michigan requires every radiation oncology facility to report yearly the number of external beam and IMRT treatments delivered. Data for 2005-2008 were obtained through a Freedom of Information Act request of the Michigan Department of Community Health, while 2009-2010 data were available at its website. Percentage of external beam treatments delivered using IMRT (IMRT%) was examined across centers over time and repeated-measures longitudinal linear regression was used to identify factors associated with use. Results: During 2005-2010, 48 to 65 centers reported data. Median IMRT% (range) rose steadily during the study period: 2005 16% (0-64); 2006 21% (0-57); 2007 27% (0-79); 2008 37% (7-85); 2009 41% (0-87) 2010 45% (7-100). There was also significant between-center variation (see table). Regression modeling demonstrated that IMRT% was associated with year (+6.7% per year, p<0.0001), facility type (+7.1% freestanding versus hospital, p<0.11), facility annual volume (+5.0% high volume: 7,000+ versus low: <7,000, p=0.01) and the interaction between year and volume (low volume +2.4% per year versus high volume p<0.02). The significant interaction between year and volume suggests that the greatest IMRT% growth was in low volume centers (6.7% per year versus 4.3% per year for high volume). Conclusions: IMRT utilization has grown steadily across Michigan between 2005 and 2010. There is significant variation in its use that appears to be related in part to facility characteristics. The newly established Michigan Radiation Oncology Quality Collaborative (MROQC) is beginning to explore the use of IMRT in patients with breast and lung cancer statewide to identify those groups of patients where improved outcomes may justify its higher cost. [Table: see text]

Publisher

American Society of Clinical Oncology (ASCO)

Subject

Cancer Research,Oncology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3