Critical Impact of Radiotherapy Protocol Compliance and Quality in the Treatment of Advanced Head and Neck Cancer: Results From TROG 02.02

Author:

Peters Lester J.1,O'Sullivan Brian1,Giralt Jordi1,Fitzgerald Thomas J.1,Trotti Andy1,Bernier Jacques1,Bourhis Jean1,Yuen Kally1,Fisher Richard1,Rischin Danny1

Affiliation:

1. From the Departments of Radiation Oncology and Medical Oncology, and Centre for Biostatistics and Clinical Trials, Peter MacCallum Cancer Centre; University of Melbourne, Melbourne, Australia; Department of Radiation Oncology, Princess Margaret Hospital, Toronto, Ontario, Canada; Department of Radiation Oncology, Hospital General Vall d'Hebron, Barcelona, Spain; Department of Radiation Oncology, University of Massachusetts Medical Center, North Worcester, MA; Department of Radiation Oncology, H. Lee...

Abstract

Purpose To report the impact of radiotherapy quality on outcome in a large international phase III trial evaluating radiotherapy with concurrent cisplatin plus tirapazamine for advanced head and neck cancer. Patients and Methods The protocol required interventional review of radiotherapy plans by the Quality Assurance Review Center (QARC). All plans and radiotherapy documentation underwent post-treatment review by the Trial Management Committee (TMC) for protocol compliance. Secondary review of noncompliant plans for predicted impact on tumor control was performed. Factors associated with poor protocol compliance were studied, and outcome data were analyzed in relation to protocol compliance and radiotherapy quality. Results At TMC review, 25.4% of the patients had noncompliant plans but none in which QARC-recommended changes had been made. At secondary review, 47% of noncompliant plans (12% overall) had deficiencies with a predicted major adverse impact on tumor control. Major deficiencies were unrelated to tumor subsite or to T or N stage (if N+), but were highly correlated with number of patients enrolled at the treatment center (< five patients, 29.8%; ≥ 20 patients, 5.4%; P < .001). In patients who received at least 60 Gy, those with major deficiencies in their treatment plans (n = 87) had a markedly inferior outcome compared with those whose treatment was initially protocol compliant (n = 502): −2 years overall survival, 50% v 70%; hazard ratio (HR), 1.99; P < .001; and 2 years freedom from locoregional failure, 54% v 78%; HR, 2.37; P < .001, respectively. Conclusion These results demonstrate the critical importance of radiotherapy quality on outcome of chemoradiotherapy in head and neck cancer. Centers treating only a few patients are the major source of quality problems.

Publisher

American Society of Clinical Oncology (ASCO)

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3