Reducing Cancer Drug Cost: 3-Year Analysis of Automated Dose Rounding in Electronic Health Records

Author:

Shah Vishal S.1ORCID,Irvine Clayton2ORCID,McWilliams Robert R.3ORCID,Singh Parminder4,Soefje Scott A.2ORCID

Affiliation:

1. Department of Pharmacy, Mayo Clinic, Phoenix, AZ

2. Department of Pharmacy, Mayo Clinic, Rochester, MN

3. Department of Medical Oncology, Mayo Clinic, Rochester, MN

4. Division of Medical Oncology, Mayo Clinic, Phoenix, AZ

Abstract

PURPOSE Globally, cancer drug expenditure exceeds $185 in US dollars (USD) billion, with the United States contributing $75 (USD) billion. Many cancer drug doses are calculated on the basis of body weight or body surface area, which often results in leftover drug in partially used single-dose vials (SDVs). The cost of wasted drug is a huge financial burden on the US health care system. We evaluated the cost savings resulting from the reduction of SDV wastage, achieved through the implementation of automated dose rounding rules in electronic health records (EHRs). METHODS Mayo Clinic implemented automated dose rounding rules within the EHR. These rules were designed to round calculated doses to the nearest SDV if the vial size closely matched the original calculated dose, within a 10% threshold. We assessed doses administered between January 2019 and December 2021, and computed cost-savings, waste reduction, and cost of waste for chemotherapy drugs. RESULTS In 3 years, 36.1% of doses were rounded down, 35.8% were rounded up, and 28.1% were exact doses. By rounding doses down to a vial size, we achieved cost-savings of $39.75 (USD) million and prevented 62,065 SDV of cancer drugs from going to waste. By rounding doses up, we avoided wasting $9.95 (USD) million worth of drugs. However, there were still instances where the rounding fell outside of the 10%, resulting in wasted drugs worth $25 (USD) million. CONCLUSION The substantial burden imposed on patients and the US health care system because of cancer drug wastage is of significant concern. Although the automated dose rounding system represents a partial solution for this issue, a comprehensive approach involves the imperative development of policy and legislative solutions to effectively mitigate the challenges associated with cancer drug waste.

Publisher

American Society of Clinical Oncology (ASCO)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3