Electronic Medical Record–Based Radiation Oncology Toxicity Recording Instrument Aids Benchmarking and Quality Improvement in the Clinic

Author:

Albuquerque Kevin1,Rodgers Kellie1,Spangler Ann1,Rahimi Asal1,Willett DuWayne1

Affiliation:

1. University of Texas Southwestern Medical Center, Dallas, TX

Abstract

Purpose: The on-treatment visit (OTV) for radiation oncology is essential for patient management. Radiation toxicities recorded during the OTV may be inconsistent because of the use of free text and the lack of treatment site–specific templates. We developed a radiation oncology toxicity recording instrument (ROTOX) in a health system electronic medical record (EMR). Our aims were to assess improvement in documentation of toxicities and to develop clinic toxicity benchmarks. Methods: A ROTOX that was based on National Cancer Institute Common Terminology Criteria for Adverse Events (version 4.0) with flow-sheet functionality was developed in the EMR. Improvement in documentation was assessed at various time intervals. High-grade toxicities (ie, grade ≥ 3 by CTCAE) by site were audited to develop benchmarks and to track nursing and physician actions taken in response to these. Results: A random sample of OTV notes from each clinic physician before ROTOX implementation was reviewed and assigned a numerical document quality score (DQS) that was based on completeness and comprehensiveness of toxicity grading. The mean DQS improved from an initial level of 41% to 99% (of the maximum possible DQS) when resampled at 6 months post-ROTOX. This high-level DQS was maintained 3 years after ROTOX implementation at 96% of the maximum. For months 7 to 9 after implementation (during a 3-month period), toxicity grading was recorded in 4,443 OTVs for 698 unique patients; 107 episodes of high-grade toxicity were identified during this period, and toxicity-specific intervention was documented in 95%. Conclusion: An EMR-based ROTOX enables consistent recording of treatment toxicity. In a uniform sample of patients, local population toxicity benchmarks can be developed, and clinic response can be tracked.

Publisher

American Society of Clinical Oncology (ASCO)

Subject

Health Policy,Oncology (nursing),Oncology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3