BOIN12: Bayesian Optimal Interval Phase I/II Trial Design for Utility-Based Dose Finding in Immunotherapy and Targeted Therapies

Author:

Lin Ruitao1ORCID,Zhou Yanhong1ORCID,Yan Fangrong2,Li Daniel3,Yuan Ying1ORCID

Affiliation:

1. Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, TX

2. China Pharmaceutical University, Nanjing, People’s Republic of China

3. Juno Therapeutics, a Bristol Myers Squibb Company, Seattle, WA

Abstract

PURPOSE For immunotherapy, such as checkpoint inhibitors and chimeric antigen receptor T-cell therapy, where the efficacy does not necessarily increase with the dose, the maximum tolerated dose may not be the optimal dose for treating patients. For these novel therapies, the objective of dose-finding trials is to identify the optimal biologic dose (OBD) that optimizes patients’ risk-benefit trade-off. METHODS We propose a simple and flexible Bayesian optimal interval phase I/II (BOIN12) trial design to find the OBD that optimizes the risk-benefit trade-off. The BOIN12 design makes the decision of dose escalation and de-escalation by simultaneously taking account of efficacy and toxicity and adaptively allocates patients to the dose that optimizes the toxicity-efficacy trade-off. We performed simulation studies to evaluate the performance of the BOIN12 design. RESULTS Compared with existing phase I/II dose-finding designs, the BOIN12 design is simpler to implement, has higher accuracy to identify the OBD, and allocates more patients to the OBD. One of the most appealing features of the BOIN12 design is that its adaptation rule can be pretabulated and included in the protocol. During the trial conduct, clinicians can simply look up the decision table to allocate patients to a dose without complicated computation. CONCLUSION The BOIN12 design is simple to implement and yields desirable operating characteristics. It overcomes the computational and implementation complexity that plagues existing Bayesian phase I/II dose-finding designs and provides a useful design to optimize the dose of immunotherapy and targeted therapy. User-friendly software is freely available to facilitate the application of the BOIN12 design.

Publisher

American Society of Clinical Oncology (ASCO)

Subject

Cancer Research,Oncology

Cited by 71 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3