Lymph node staging in non-small-cell lung cancer with FDG-PET scan: a prospective study on 690 lymph node stations from 68 patients.

Author:

Vansteenkiste J F,Stroobants S G,De Leyn P R,Dupont P J,Bogaert J,Maes A,Deneffe G J,Nackaerts K L,Verschakelen J A,Lerut T E,Mortelmans L A,Demedts M G

Abstract

PURPOSE To compare the accuracy of computed tomography-(CT) scan and the radiolabeled glucose analog 18F-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) visually correlated with CT (PET + CT) in the locoregional lymph node (LN) staging of non-small-cell lung cancer (NSCLC). PATIENTS AND METHODS Sixty-eight patients with potentially operable NSCLC underwent thoracic CT, PET, and invasive surgical staging (ISS). Imaging studies were read prospectively and blinded to the surgical and pathologic data. A five-point visual scale was used for the interpretation of LNs on PET. Afterwards, with knowledge of the pathology, the relationship between standardized uptake values (SUVs) and the presence of metastasis in LNs was explored in a receiver operating characteristic (ROC) analysis, and the likelihood ratios (LRs) for SUVs of LNs were determined. RESULTS ISS was available for 690 LN stations. CT correctly identified the nodal stage in 40 of 68 patients (59%), with understaging in 12 patients and overstaging in 16 patients. PET + CT was accurate in 59 patients (87%), with understaging in five patients and overstaging in four patients. In the detection of locally advanced disease (N2/N3), the sensitivity, specificity, and accuracy of CT were 75%, 63%, and 68%, respectively. For PET + CT, this was 93%, 95%, and 94% (P = .0004). In the ROC curve, the best SUV threshold to distinguish benign from malignant LNs was 4.40. The analysis with this SUV threshold was not superior to the use of a five-point visual scale. The LR of a SUV less than 3.5 in an LN was 0.152; for a SUV between 3.5 and 4.5, it was 3.157; and for a SUV greater than 4.5, it was 253.096. CONCLUSION PET + CT is significantly more accurate than CT alone in LN staging of NSCLC. A five-point visual scale is as accurate as the use of an SUV threshold for LNs in the distinction between benign and malignant nodes. The very high negative predictive value of mediastinal PET could reduce the need for mediastinal ISS in NSCLC substantially.

Publisher

American Society of Clinical Oncology (ASCO)

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3