Author:
Ludington-Hoe Susan M.,Morrison-Wilford Barbara L.,DiMarco Marguerite,Lotas Marilyn
Abstract
PurposeThe aim of this project was to evaluate the implementation of the Respiratory, Activity, Perfusion, Position, and Tone (RAPPT) instrument in assessing the infant’s transition to extrauterine life while in skin-to-skin contact (SSC).Sample/DesignNurses (n = 17) completed a pretest and posttest of RAPPT and Apgar scoring knowledge, attended an in-service about accurate scoring, and were observed during 17 deliveries when newborns were in SSC.Outcome VariablesPrimary variables were knowledge scores, use of RAPPT, and accurate RAPPT scoring. Apgar scoring was also measured.ResultsKnowledge scores increased significantly after education, RAPPT scores were correctly assessed, and 1 of 17 newborns had a sudden unexpected postnatal collapse. Apgar scoring accuracy did not change and nurses reported that their Apgar scores were based on their overall impressions of the infant instead of Apgar criteria.
Publisher
Springer Publishing Company
Subject
Critical Care and Intensive Care Medicine,Critical Care Nursing,General Medicine,Pediatrics, Perinatology and Child Health
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献